![Johnson Controls Kantech tyco ioSmart Скачать руководство пользователя страница 38](http://html.mh-extra.com/html/johnson-controls/kantech-tyco-iosmart/kantech-tyco-iosmart_installation-manual_2023439038.webp)
Configuring the reader
This section describes how to configure the reader by short circuiting the wires on the terminal, and
how to configure the reader using your Kantech smart card.
Configuring the reader using the terminals
Use this section to configure the reader using the terminals.
Note:
If RS-485 communication is not detected when you turn on the reader, it transmits
Wiegand format according to its configuration.
Factory default (SSF transmission format)
Figure 18: Factory default terminal block shorting diagram
SSF is the factory default configuration.
Important:
Forcing the reader to factory default deletes all custom settings from the reader
and defaults BLE credential data. If you factory default a panel-less reader, you may need to
contact technical support to reset it.
To return the reader to the factory default configuration, complete the following steps:
1. Short circuit together the D0 and BUZ terminals.
2. Short circuit together the D1 and LED terminals.
3. Apply power to the reader.
A simultaneous sequence of four beeps and flashes, four times, indicates a successful return to
the SSF transmission format.
A sequence of rapid beeps and flashes for 4 seconds indicates that the device has not returned
to the SSF transmission format.