View Bypass
The keypad shows the Bypass if pres-
ent:
BYPASS! 001/003
Zone
001
Ø
the display top line shows the current bypass dis-
played respect to the total of bypass, on the right;
Ø
the display bottom line shows the label of the by-
passed zone.
16.
Press
ENTER
to skip to “View Partition and System
status”.
Press
A
to view the next bypass: if there are no
more bypasses to view, the display shows the Parti-
tion and System status.
View Partition and System status
The keypad shows
the status of the partitions and the system:
Feb/04/11
14:32
DDDDDDDD
Ø
The display top line shows the date and time.
Ø
The display bottom line shows the state of the first 8
Partitions, on the left, as follow.
D
: Disarmed.
A
: Away Armed.
S
: Stay Armed.
I
: Instant Armed (Stay/Away with Zero Delay).
–
: Not assigned to the Keypad.
Ø
The following information on the right.
Icon
Signalled
b
y
Description
S
x
Control panel tamper (opened or wall re-
moved)
T
x
System tamper (
AS
terminal)
b
x
Peripheral tamper (keypad, key reader, ex-
pander IN/OUT, power station, transceiver)
f
x
False key
s
x
Peripheral lost (keypad, key reader, expander
IN/OUT, power station, tranceiver)
t
*
Installer access enabled (locally and re-
motely)
r
*
Answerphone facility enabled
i
Telephone line busy
17.
Press
ENTER
to view the Option Menu.
INSTALLER
1act. 2prg 3view
18.
Select the required option then go to the relative
paragraph: you can either select the required op-
tion group by pressing the relative key then scroll to
the required option by pressing the key
a
and
b
, or
you can directly go to the required option by enter
its address as indicated following.
r
1
: actions
Ø
1.1
: Zone Test
Ø
1.2
: Output Test
Ø
1.3
: Changing the PIN
Ø
1.4
: Firmware Upgrade by an USB key
Ø
1.5
: Logger Downloading on a USB key
Ø
1.6
: Modify the LCD Keypad language
Ø
1.7
: Enabling Level 4 access
Ø
1.8
: Clear Faults and Tampers
Ø
1.9
: Option Programming by Keypad
r
2
: programming
Ø
2.1
: Voice Message Recording
Ø
2.2
: BPI Device enrolling
Ø
2.3
: Wireless Device enrolling
Ø
2.4
: Key (card/tag) enrolling
Ø
2.5
: Message Download/Upload via USB Key
Ø
2.6
: Option Download/Upload via USB Key
Ø
2.7
: Factory Default
Ø
2.8
: Telephone Communicator
Ø
2.9
: Key Disabling/Enabling
r
3
: view
Ø
3.1
: View Logger
Ø
3.2
: View the Firmware Version
Ø
3.3
: View Zone Status and Zone Bypassing
Ø
3.4
: View GSM Module Status
Ø
3.5
: View IP Module Status.
Quit from the Operations
Press
ESC
until the display shows the following mes-
sage (if you are on the Installer Level):
INSTALLER
Exit ?
or the following message (if you are on the Level 4):
LEVEL 4
Exit ?
Press
ENTER
to confirm.
+
The keypad quit from the operations even when
you do not press any key before the timeout ex-
pires: you have
30 seconds
timeout when the key-
pad is displaying information about the system
(Alarms, Tampers, Faults, Bypass, Partitions and
Status) and
180 seconds
when in the option
menu.
102