 Model: 

ASG-TP20FAS1

  

ASG-TP20FBS1

Installation Manual for Snow Protection Hood (for Outdoor Unit)

This snow protection hood prevents snow from entering the outdoor unit and to prevent strong winds  from 
blowing against the heat exchanger.  Be sure to read this manual carefully for correct performance before 
installation work.

IMPORTANT NOTICE:

•  Johnson Controls pursues a policy of continuous improvement in design and performance of products. We

reserve the right to vary speci

fi

 cations without notice.

•  No part of this manual may be reproduced without Johnson Controls’ written permission.
•  Keep this manual for future reference.
•  Johnson Controls cannot anticipate every possible circumstance that might involve a potential hazard.
•  This kit is designed for a combination of Johnson Control air conditioners. Do not use this kit by itself or in

combination with other companies’ air conditioners.

•  To hold the snow protection hood properly to the outdoor unit against the strong wind or earthquake, stay 

or safety wire rope shall be used for reinforced installation.  Use the 

fi

 eld-supplied safety wire rope to 

prevent outdoor unit from overturning.

•  Perform a test run after installation to check for abnormalities.
•  Signal words are used to identify levels of hazard seriousness. De

fi

 nitions for identifying hazard levels are 

provided below with their respective signal words.

 

  :  Indicates a hazardous situation that, if not avoided,

 

  could result in death or serious injury.

 

  :  Indicates a hazardous situation that, if not avoided,

 

  could result in minor or moderate injury.

1. Applicable Unit

NOTE

:

The applicable outdoor unit may be different depending on the product series.  Be sure to con

fi

 rm with 

the product catalogue before installation.

Name

Hood for Air Outlet

Model

ASG-TP20FAS1

ASG-TP20FBS1

Applicable Outdoor Unit

Top Flow Type 

72,000 Btu/h

Top Flow Type 

96,000 and 120,000 Btu/h

2. Installation Work

(1)  After the snow protection hood is installed, electromagnetic noise at the air outlet side may slightly 

increase.  Therefore, it is necessary to carefully consider the air discharge direction when installed.

(2)  Be sure to tighten the snow protection hood securely to the top panel and side panel of the outdoor 

unit with the supplied screws (accessories).  Not doing so may cause vibration or abnormal noise.

(3)  There must be no obstacles in the air discharge direction of the snow protection hood.  If there are, it 

may cause a short circuit or an insuf

fi

 cient air

fl

 ow rate.

(4)  Do not install other outdoor units in the direction of air outlet.  If the air blown out of the snow protection 

hood is sucked into the other outdoor unit, it may cause of a malfunction of the unit.

(5)  The wind loads which the outdoor unit receives changes by attaching the snow protection hood.  The 

required installation strength will also change in strong wind.  Therefore, recheck the strength of the 
anchor bolts of the outdoor unit.

(6)  If the snow protection hood is installed, cooling/heating performance may be slightly lowered 

depending on the usage conditions.

1

Содержание ASG-TP20FAS1

Страница 1: ...avoided could result in death or serious injury Indicates a hazardous situation that if not avoided could result in minor or moderate injury 1 Applicable Unit NOTE The applicable outdoor unit may be d...

Страница 2: ...Increase the base height or additionally provide the frame under the unit higher than snow accumulation and fix the outdoor unit securely with anchor bolts 2 Secure enough service space with considera...

Страница 3: ...Plate for Right Side Front Side 1 1 10 Fixing Plate for Right Side Rear Side 1 1 11 Screw for Installation M5 x 15 32L 12L tapping screw type B 10 2 10 2 For installation accepting burring TP hole 2...

Страница 4: ...e 1 and left side plate 2 together two places by using screws for assembling 12 2 Tighten the horizontal plate 6 in four places by using screws for assembling 12 3 Tighten the faceplate three pieces 4...

Страница 5: ...w protection hood for the air outlet with those removed screws 4 Tighten the faceplate 3 5 by using screws for assembling 12 Screws for Assembling 12 ASG TP20FAS1 11 places ASG TP20FBS1 12 places 5 12...

Страница 6: ...ht side front side 9 fixing plate for the right side rear side 10 with the screws for assembling 16 places 11 or 12 Use the screws in specified positions as shown in the figure 12 12 12 10 8 11 11 11...

Страница 7: ...Applicable Outdoor Unit Model Top Flow Type 72 000 Btu h Top Flow Type 96 000 and 120 000 Btu h Hood for Air Outlet ASG TP20FAS1 ASG TP20FBS1 Hood for Rear Side Air Inlet ASG TP20BAS1 ASG TP20BBS1 Ho...

Страница 8: ...t is generated or coating film is peeled cracked scour the rust off or apply touch up coating When recoating such parts be sure to grind the coating using sandpaper 180 to 230 before re applying coati...

Отзывы: