438335-UIM-C-1209
22
Johnson Controls Unitary Products
FIGURE 27:
Horizontal Right Configuration
AIRFLOW
HORIZONT
AL
-
RIGHT
INDUCER
ROT
A
TED
HORIZONT
AL
-
RIGHT
INDUCER
AS
RECEIVED
Move
rain
gutter
hose
to
this
position.
Move
pressure
switch
hose
to
this
position.
Change
condensate
drain
connection
to
the
90°
fitting
provided.
Move
condensate
drain
hose
to
this
position.
Move
rain
gutter
hose
to
this
position
Change
condensate
drain
connection
to
the
90°
fitting
provided
Move
condensate
drain
hose
to
this
position
AIRFLOW
Move
pressure
switch
hose
to
this
position.
When
drain
hose
routing
changes
are
required,
be
sure
to
cap
all
un-used
openings.
If
rerouting
hoses
-
excess
length
should
be
cut
of
f
so
that
no
sagging
loop
s
will
collect
and
hold
condensate,
which
will
cause
the
furnace
to
not
operate.
2
3
4
1
1
2
3
4