Chapter 2 Diagnostic Codes
2-20
2.9.4 ERROR ID
The table lists the error codes and gives some examples for an error.
Error ID
Limits
F01
Not complete
F02
Invalid job
mod 2D, Brake : module gets invalid event.
mod 49, Drive system : Internal error, command not valid in actual mode of
operation
mod 66, meas Control : Internal error. module gets invalid user event.
command not valid in actual mode of operation
mod C1, Self-test : Self-test failed, see error record for more information
(kernel register err0,...err9 or user interface: C28).
F03
Out of memory
F04
Out of range
mod 27, Temperature: Out of Range
F05
Buffer full
F06
Channel not found
F07
Not found
mod 41, ASS : Time client not found
mod 44, SAPE : Time service not found during unregister
mod C1, Self-test : Self-test failed, result of test invalid
F08
Already exists
F09
In use
mod 44, SAPE : AWP already in use
mod 49, Drive system : Internal error, command not valid in actual mode of
operation
many “490F09” errors in the error record indicates a
malfunction of the pedal.
F0A
End of file
F0B
Drive full
F0C
Bad name
F0D
Xmit error
mod C3, user Interface : Communication Error between balancing kernel and
user
interface (BK <- uI). machine should be restarted.
This error can caused by a bad connection of the RS2
-
32-E
serial line. Check external and internal cabling.
F0E
Format failed
F0F
Bad parameter
mod 41, ASS : Invalid time specified
mod 44, SAPE : Bad parameter during calling time service
mod 81, cmd : Parameter of a kernel command is bad.
Such an error can occur as a result from a hardware
malfunction.
F10
Bad medium
Содержание EEWB304B