User Manual LiVE III AGO
35
6.
Activate the MIDI stop which has to be configured. The settings of the
corresponding MIDI stop appear on the display. An pointer is located in front
of the value of the MIDI channel.
7.
Use the - and + pistons to select the desired MIDI channel.
8.
Press the ENTER-piston. The pointer jumps to the MSB value.
9.
Use the - and + pistons to select the desired MSB value.
10.
Press the ENTER-piston. The pointer jumps to the LSB value.
11.
Use the - and + pistons to select the desired LSB value.
12.
Press the ENTER-piston. The pointer jumps to the Voice value.
13.
Use the - and + pistons to select the desired Voice value.
14.
Press the ENTER-piston. The selected configuration is now stored in memory.
The pointer jumps back to the MIDI channel location.
15.
Press the MENU piston three times to exit the Johannus Menu.
5.5.7
Reset
The Reset function can be used to reset a number of setting per sample set to the
factory settings.
1.
Press the MENU-piston.
2.
Use the - and + pistons to select the
Organ Settings
function on the
display.
3.
Press the ENTER-piston. A list with available Organ Settings appears on the
display.
4.
Use the - and + pistons to select the
Reset
function on the display.
5.
Press the ENTER-piston. The available Reset functions appear on the display.
6.
Use the - and + pistons to select the desired reset procedure:
Crescendo default
:
Resets to factory settings of the 20
steps of the crescendo pedal.
Cust. Temperament def.
:
Resets the custom programmable
temperament to equal temperament.
Expression Pedals def.
:
Resets to factory settings of the
expression pedals.
Intonation default
:
Resets to factory settings of the
intonation.
Memory default
:
Clears the entire capture memory.
MIDI default
:
Resets to factory settings of the MIDI
stops.
Preset default
:
Resets to factory settings of the pre
programmed memory locations.
7.
Press the ENTER-piston. A question to confirm appears on the display.
8.
Use the - and + pistons to select
No
or
Yes
. Press the ENTER-piston to
confirm and to return to the Reset menu.
9.
Press the MENU piston three times to exit the Johannus Menu.