background image

ٛ

 

b. Remove the connecting screws around the bottom pan and the screws to 

thecirculation motor support, the drain motor and the pressure switch bracing bar. 

ٛ

 

c. Check the capacitor and, if necessary, replace a new one. 

 

ٛ

 

d. Check the circulation pump for defects. In case of defective pump, replace it 

inthe following manner: 
 

ٛ

 

(1) Remove the inlet hose clamp and the circulation pump; 

 

ٛ

 

(2) Replace a new circulation pump; 

ٛ

 

(3)Put on a new inlet hose clamp and connect the tubes and wires; 

ٛ

 

(4) Tighten the clamp. 

 
 

e. Check the drain pump for defects. In case of defective pump, replace it in the 

 
 

following manner:(1)Remove the inlet hose clamp and the drain pump; 

ٛ

 

(2) Replace a new drain pump;   

ٛ

 

(3) Put on a new inlet hose clamp and connect the tubes and wires;   

ٛ

 

(4) Tighten the clamp.   

ٛ

 

f. Check the connecting tubes and replaced the damaged ones.   

 
Removal of Drainage Troubles   

ٛ

 

a. Check the drain hose for twist, air bubble or blockage and make necessary 

correction.  

ٛ

 

b. Check whether the motor is burnt. If so, replace the drain pump as specified 

above.  
 

XIV. Overheat Thermostat   

This thermostat is designed to prevent overheating of the heating element. 
Thetemperature limitation is set at 90 . Below this limitation, the circuit is closed. 
Oncethe temperature rises above this limitation, the circuit is cut, protecting the 
heatingelement from being burnt.Removal and replacement:Remove the outer 
casing.Remove the thermostat connecting wire and check with an ohmmeter whether 
thethermostat circuit is closed in normal temperature and opened when temperaturerises 
above 90 . If the result if positive, the thermostat is normal. Otherwise, it failsand shall be 
replaced.From the lower left side, you can see the thermostat at the end of the 
sump.Remove the nuts on the thermostat mounting plate.Remove the mounting plate 
and the thermostat.Replace a new thermostat and add some heat conducting silicone 
grease to its end.Wrench tight the nuts on the thermostat mounting plate and connect 
the thermostatconnecting wires.Replace the outer casing. 

XV. Water Temperature Thermostat   

This thermostat is designed to inspect the water temperature and control theheating 
element. The temperature control point is set at 45 (different temperaturesare available 
and can be observed from the thermostat). The circuit is openedbelow this temperature 
and closed above it.Removal and replacement:Remove the outer casing and bottom 
pan.Remove the connecting wires behind the sump and check with an ohmmeterwhether 
the thermostat circuit is opened in normal temperature and closed whentemperature 
rises above 67 . If the result if positive, the thermostat is normal.Otherwise, it fails and 
shall be replaced.Remove the screws and the mounting plate. 
Replace a new thermostat and the mounting plate. The mounting plate shall press tight 

Содержание DW5A

Страница 1: ...dishwater Cross screwdriver Common screwdriver Torque spanner OTK caliper and universal meter Attention never measure the resistance of live cord Otherwise you measuring device may be damaged The tro...

Страница 2: ...l Replace the electric control The cover of the softener is loosed Tighten the cover Salt leakage for equipped with softener The o ring of the cover is inversed Replace the o ring Door switch is damag...

Страница 3: ...ump Replace the pump Poor clearing No salt in the softener Add salt to the softener Improper loading of dishes pots etc The wrong wash program be chosen Instruct the customer on proper loading of the...

Страница 4: ...nser and add without delay if it is insufficient The brightness liquid helps the water to drip making the dishes easy to dry and curbing the formation of water specks on the surface of the dishes V Po...

Страница 5: ...ng wire connects the I O PCB the power switch the inlet valve the heating elements and other electric elements together The wires shall be kept intact Any damage to the wire may cause overheat and res...

Страница 6: ...ack the circuit from the electrical controller to any element The electrical controller is a very reliable unit In case of dishwasher troubles check other causes first before focusing on and replacing...

Страница 7: ...hwasher to OFF and pull out the power cord plug guard against sharp edge from hurting the power cord b Check with an ohmmeter as instructed c Remove the outer casing and the rear panel d Check the con...

Страница 8: ...itation switch and a safety device Incase the dishwasher fails and the temperature inside the inner container risesabove a specific limitation the thermostat will cut the heating element circuit toavo...

Страница 9: ...lement from being burnt Removal and replacement Remove the outer casing Remove the thermostat connecting wire and check with an ohmmeter whether thethermostat circuit is closed in normal temperature a...

Страница 10: ...dispenser and the two locknuts and remove the inner door c Check the dispenser for any leakage or release of brightness liquid If no brightness liquid is released check if there is brightness liquid...

Страница 11: ...White DW5AL Pressure switch for heater...

Страница 12: ...d Wiring diagram Foshan Shunde Midea Washing Appliances Mfg Co Ltd diagram Approved by Peter Manufactory Model Number DW5HL Issue date 2009 3 17 Kesa model number CDW400P Compan chop Product name Dish...