7
IR Test LED Off:
Optical Interference.
IR Test LED On or Flickering:
Electromagnetic Interference.
EMI (Electromagnetic Interference):
Solution:
1. Move the Receiver or the Receiver cable away
from the EMI source or move the source of the EMI
away from the Receiver or the cable.
2. Connect the Receiver’s GND terminal to true earth
ground (if this isn’t feasible use the Connecting
Block’s GND terminal).
There are many methods for reducing interference.
Which solution is best for you depends on your
situation. If you require further assistance contact
JobSite Technical Support at 1-866-458-7483.
SPECIFICATIONS
IR system:
Works with practically all brands of IR remote controls
IR receiving (varies by brand of remote control):
18’-30’ range, 30 degrees off-axis
Wiring requirements:
Category 5 or better, Home runs required
Mounting:
Single gang electrical box at least 2-3/4” deep
Dimensions:
1-5/8” wide x 2-5/8” high x 2-3/4” deep
Depth behind faceplate:
2-3/4”
Warranty: 2 year limited