Battery Charger Fault Codes
(See “Errors Menu” on page 20 info for display information)
Table 6-13. Battery Charger Fault Codes
CODE
DESCRIPTION
STATUS
ACTION
8
Internal logic fault.
Battery charger stops working.
Contact service dept. or change product.
13
Communication problem with external memory.
Battery charger stops working.
Contact service dept. or change product.
18
Extended shutdown or power failure.
Battery charger stops supplying power. Operation
resumes as soon as alarm conditions are no longer
present or after restarting.
If problem is a power failure, check battery charger
mains power supply.
19
Internal logic fault.
Battery charger stops working.
Contact service dept. or change product.
240
Digital input is open and managed as hardware
start-stop.
Battery charger stops charging until digital input
closes.
Close digital input.
241
Problem in CANBUS communication with other sys-
tems in the network.
The way this is managed may change based on dif-
ferent firmware releases.
Check correct operation of CANBUS system.
242
Error when reading internal memory on micro con-
troller.
Battery charger stops working.
Contact service dept. or change product.
244
Mains voltage lower than maximum operating
range tolerance.
Battery charger won’t start charging until mains
voltage returns within normal operating range.
Make sure mains voltage is within correct operating
parameters.
245
Abnormal current draw in primary section.
Battery charger stops supplying power. Operation
resumes as soon as alarm conditions are no longer
present.
If problem persists, contact service dept. or change
product.