SECTION 6 - GENERAL SPECIFICATIONS AND OPERATOR MAINTENANCE
6-24
– JLG Lift –
3121773
BMS Fault Codes - (Battery Management System)
(See “Errors Menu” on page 20 info for display information)
NOTE:
The CODE column indicates the CAN CODE in the mes-
sage sent by the battery charger. The normal mains
voltage tolerance is the rated value ±15%.
CODE
–
TYPE OF ERROR
A99E01 – Configuration error
A99E02 – Incorrect voltage
A99E03 – Incorrect temperature
A99E04 – Excess discharge current
A99E05 – Excess charge current
A99E06 – Pre.charge error
A99E07 – No 12 V power supply
A99E08 – No 12 V power supply
A99E09 – High battery compartment temperature
A99E10 – High electronic board temperature
A99E11 – Incorrect self.protection device temperature
A99E12 – Fault on all temperature sensors
A99E13 – Temperature sensor fault
A99E14 – Earth connection fault
A99E01 – Incorrect system configuration
A99E02 – Incorrect voltage
79
Incorrect start
Cause – Incorrect starting procedure.
Solution – Check electrical connections. This is generally a temporary
problem due to certain working conditions. If problem persists, replace
inverter.
86
Pedal wire KO
Cause –
Solution – This is generally a temporary problem due to certain working
conditions. If problem persists, replace inverter.
93
Wrong set batt
Cause – With power connected, battery test detected incorrect batteries
fitted.
Solution – Replace batteries with the original ones supplied directly by
JLG.
94
Current sensor KO
Cause – Set up procedure for maximum current in progress.
Solution – Contact JLG after-sales service.
99
Check up needed
Cause –
Solution – Contact Hinowa after.sales service.