Table 7-1. Troubleshooting
Base will not level (DO NOT ELEVATE UNLESS BASE FIRM AND LEVEL)
Castor deployed
With no load in platform and people clear of adjustable feet - exert approximately
25kg pressure onto front of base. Castor should retract. Adjustable feet should
then be able to be used to level the machine on slopes less than 2 degrees front to
back. Do not use the machine on any side slope.
Machine rocks slightly side to side
Support surface is not level
Only use the machine on firm and level surfaces.
Adjustable feet are not BOTH in contact with
supporting surface
Adjust the feet so that BOTH feet are in firm contact with supporting surface AND
the machine is level.
Ropes are worn or a rope is broken or machine is 5 years old or machine has been in service for 5 years since previous service
Damage or wear or machine is 5 years old
Deliver unit to an Authorized JLG Service Center for replacement.
Platform will not lift full rated load
Battery not fully charged
Charge or replace battery.
Overload clutch is slipping
Contact Authorized JLG Service Center.
TROUBLE
PROBABLE CAUSE
REMEDY