SECTION 7 - TROUBLESHOOTING
1001070451
LIFTPOD by JLG
1-877-254-3876
7-2
www.liftpod.com
1-877-2-LIFTPOD
Powerpack (optional) motor does not start
Emergency stop button is engaged (PUSHED
IN) on powerpack
Disengage emergency stop button until it pops up (TURN CLOCKWISE).
Direction selector or enable trigger or speed
control trigger not activated
Select 'UP' on direction selector, then activate both the enable trigger and speed
control continuously for operation.
Battery not installed or no charge
Properly install charged battery in powerpack.
Motor has overheated
Wait until motor cools. The temperature cutout resets itself automatically.
Alternatively use manual descent procedure to lower platform (Section 4.1).
Platform does not lift up from bottom of travel - motor starts
Driveshaft interlock is engaged
Push cordless drill on driveshaft down firmly to disengage driveshaft safety inter-
lock.
(If using powerpack) Powerpack driveshaft not
engaged
Check powerpack is correctly fitted to platform, latch is down and drive shaft is
connected to carriage drive shaft.
Emergency brake not released from carriage
lock down latch position
Ensure a load greater than 50kg (110 lbs.) is in the platform (1 person) and lifting
ropes are tight. If latch has not released, attempt to lower the loaded platform
slightly then try again to lift up.
TROUBLE
PROBABLE CAUSE
REMEDY
FS.book Page 2 Wednesday, February 11, 2009 11:54 AM