SECTION 7 - BASIC ELECTRICAL INFORMATION & ELECTRICAL SCHEMATICS
7-10
31215031
7.6
DEUTSCH CONNECTORS
DT/DTP Series Assembly
1.
Grasp crimped contact about 25mm behind the contact
barrel.
2.
Hold connector with rear grommet facing you.
3.
Push contact straight into connector grommet until a
click is felt. A slight tug will confirm that it is properly
locked in place.
4.
Once all contacts are in place, insert wedgelock with
arrow pointing toward exterior locking mechanism. The
wedgelock will snap into place. Rectangular wedges are
not oriented. Thy may go in either way.
NOTE:
The receptacle is shown - use the same procedure for plug.
DT/DTP Series Disassembly
5.
Remove wedgelock using needlenose pliers or a hook
shaped wire to pull wedge straight out.
6.
To remove the contacts, gently pull wire backwards,
while at the same time releasing the locking finger by
moving it away from the contact with a screwdriver.
7.
Hold the rear seal in place, as removing the contact may
displace the seal.
Figure 7-12. DT/DTP Contact Installation
A
B
C
D
Figure 7-13. DT/DTP Contact Removal
A
B
C
Go
to
Discount-Equipment.com
to
order
your
parts