SECTION 6 - JLG CONTROL SYSTEM
6-16
31215031
6.2
MACHINE PERSONALITY SETTINGS
NOTE:
Personality settings can be adjusted within the adjustment
range for optimum machine performance.
Table 6-2. Personality Ranges/Defaults
FUNCTION
PERSONALITY
RANGE
DEFAULTS
Drive Pump
M46-XXX
Drive Pimp
830XXXX
DRIVE
Acceleration
0.0s to 5.0s
2.0
2.0
Deceleration
0.0s to 3.0s
2.0
2.0
Forward Minimum Speed
1 to 35%
4
4
Forward Maximum Speed
1 to 100%
50
97
Reverse Minimum Speed
1 to 35%
4
4
Reverse Maximum Speed
1 to 100%
50
97
Elevated Maximum Speed
1 to 100%
15
62
Creep Maximum Speed
1 to 90%
20
45
STEER
Maximum Speed
1 to 100%
100
100
MAIN LIFT
Acceleration
0.0s to 5.0s
2.0
2.0
Deceleration
0.0s to 3.0s
0.7
0.7
Minimum Up Speed
1 to 60%
60
60
Maximum Up Speed
1 to 100%
75
75
Creep Up Speed
1 to 65%
65
65
Minimum Down Speed
1 to 60%
50
50
Maximum Down Speed
1 to 100%
80
80
Creep Down Speed
1 to 75%
72
72
TOWER LIFT
Acceleration
0.0s to 5.0s
1.0
1.0
Deceleration
0.0s to 3.0s
0.5
0.5
Minimum Up Speed
1 to 60%
45
45
Maximum Up Speed
1 to 100%
100
100
Minimum Down Speed
1 to 60%
45
45
Maximum Down Speed
1 to 100%
100
100
Medium Speed
0.01 to 1.00
0.30
0.30
Go
to
Discount-Equipment.com
to
order
your
parts