SECTION 3 - MACHINE CONTROLS, INDICATORS, AND OPERATION
31215084
3-3
3.5 GROUND CONTROL STATION
DO NOT OPERATE FROM GROUND CONTROL STATION WITH PERSONNEL IN
PLATFORM EXCEPT IN AN EMERGENCY.
NOTE:
When machine is shut down, the ground control emer
-
gency stop switch must be positioned to OFF to prevent
draining the batteries.
1. Power/Emergency Stop -
A two-position red mush
-
room shaped switch furnishes power to Platform/
Ground Select switch when pulled out (on). When
pushed in (off), power is shut off to the Platform/
Ground Select switch.
2. Platform/Ground Select -
A three position, key oper
-
ated switch supplies power to platform control con
-
sole when positioned to platform. With the key held in
the ground position, power is shut off to platform and
only ground controls are operable.
NOTE:
With Platform/Ground Select in center position, power is
shut off to controls at both operating stations.
1
2
3
4
5
6
7
8
OAD01770
1.
Platform/Ground Select Switch
2.
Circuit Breaker
3.
Emergency Stop Switch
4.
Lift/Lower Switch
5.
System Fault Indicator
6.
Generator Switch (Optional)
7.
Overload Indicator (LSS)
8.
Hourmeter