![JLG 3124288 Скачать руководство пользователя страница 27](http://html1.mh-extra.com/html/jlg/3124288/3124288_manual_2020135027.webp)
SECTION 3 - OPERATION - (ES, RT)
3-4
– JLG Lift –
3124288
Pressing the ENTER key will confirm that the platform is
empty (except for factory-installed options outside the
Rated Load). The LSS Module will calculate the total of all
load cell readings and ensure that the total is greater than
minimum calibration value, but less than maximum cali-
bration value. If successful, the Analyzer will show the fol-
lowing:
CALIBRATE:
COMPLETE
If the empty platform weight is less than minimum calibra-
tion value, the calibration attempt will be unsuccessful and
the Analyzer will show the following:
CALIBRATE:
< MIN CAL
If the empty platform weight is greater than maximum cali-
bration value, the calibration attempt will be unsuccessful
and the Analyzer will show the following:
CALIBRATE:
> MAX CAL
Table 3-5. Calibration Values
MODELS
ES
RT
Minimum Calibration Value
45 KG
(99 LB)
225 KG
(496 LB)
Maximum Calibration Value
275 KG
(606 LB)
1020KG
(2249 LB)
Go to Discount-Equipment.com