![JLG 15MSP Series Скачать руководство пользователя страница 29](http://html1.mh-extra.com/html/jlg/15msp-series/15msp-series_operation-and-safety-manual_2020001029.webp)
SECTION 3 - MACHINE CONTROLS, INDICATORS AND OPERATION
3121230
– JLG Lift –
3-3
Battery - Low Voltage Warning Indicators
The MVL/MSP Platform Control Console and Ground Control Station indicate battery low voltage at three (3) Warning Levels.
Table 3-1. Battery Low Voltage Warning Indicators.
WARNING
LEVEL
INDICATOR LOCATION
RESULT
ACTION REQUIRED TO CLEAR FAULT
PLATFORM CONTROL LED
GROUND CONTROL LCD
LEVEL-1
• 3 LEDs/BARS Flashing with an audible
beep.
• Machine will Operate - No Control
Functions Locked Out.
Charge batteries to a level of four (4)
LEDs/BARS or more before operating.
LEVEL-2
• 2 LEDs/BARS Flashing with an audible
beep.
• Platform Lift-UP Function is Locked
Out.
Charge batteries for a minimum of four
(4) continuous hours or eight (8) LEDs/
BARS lit before operating. (a)
LEVEL-3
• 1 LED/BAR Flashing with an audible
beep.
• Drive and Platform Lift-UP Functions
Locked Out.
Charge batteries for a minimum of four
(4) continuous hours or eight (8) LEDs/
BARS lit before operating. (a)
NOTE:
(a) To maximize battery life, it is recommended that the factory supplied batteries be charged continuously for a minimum of 4 hours or until 8 bars are lit on the ground station LCD Display
before operating the machine. When drained to Warning Level 2 or 3, batteries must be charged until 8 bars are lit on the ground station LCD display to clear the fault code.