PAGE
36
of
131
#
TITLE
DESCRIPTION
VALID
RANGE
DEFAULT
1
Units In=0/MM=1 Changes the measurement units for
display and user entry. When set to
0, units measure in inches. When set
to 1, units measure in millimeters.
0-1
1
2
Scan Steering
%max
Sets the steering limit maximum
when using the jog mode scan
setting. Lower values make the
steering joystick less sensitive and
more accurate enabling better control
following a guide or feature. Units
are a percentage of the maximum
system allowed.
0-100
100
3
Rapid Steering
%max
Sets the steering limit maximum
when using the Rapid setting within
Jog mode. Recommended to be left
at 100 to allow maximum crawler
maneuverability.
0-100
100
4
Crawler Scan
unit/s
Sets the crawler scan rate in the
current units/second. This setting can
also be changed through the Jog or
Two Axis Scan Speed screens
0-254 mm/s
(0-10 in/s)
76 mm/s
(3.0 in/s)
5
Crawler Rapid
unit/s
Sets the crawler rapid rate in the
current units/second. This setting
can also be changed through the Jog
screen.
0-254 mm/s
(0-10 in/s)
254 mm/s
(10 in/s)
6
Raster Scan
unit/s
Sets the raster arm scan rate in the
current units/second. This setting can
also be changed through the Jog or
Two Axis Scan Speed screens.
0-923 mm/s
(0-36.3 in/s)
92 mm/s
(3.6 in/s)
7
Raster Rapid
unit/s
Sets the raster arm rapid rate in the
current units/second. This setting
can also be changed through the Jog
screen.
0-923 mm/s
(0-36.3 in/s)
923 mm/s
(36.3 in/s)