background image

Operation & Installation Instructions

       Riverina SRS3 Insert

Please keep these instructions for future reference.

Rev A

231312

Riverina SRS3 Insert

12

A.F. Gason Pty Ltd reserves the right to modify or alter specifications, material etc. in the intrest of product improvement

WARRANTY

 

Smoke entering the room from the firebox when the door is open may be caused by

 

 

Insufficient length of flue (Flue to be 4500mm minimum underneath the base of heater to 
underside of cowl)   

Increase height of flue 

 

Flue downdraught 

Consult dealer or increase height of flue. 

 

Creosote buildup in flue  

Remove cowl and clean flue as per cleaning instructions. Check moisture content of wood. 
 

 

Excessive ash build up 

Some woods will give large amounts of ash despite how you run the heater. Others will give you very little. 
Use the wood which is most convenient for you as long as it is dry. After a period of time you will get to 
know when to empty your unit. Bark will give you excessive ash. Try not to burn it.

 

If you are burning wood that gives you charcoal, you may find that after running the heater say for 8 hours 
at maximum burn rate, the charcoal builds up excessively. Overnight burn will reduce this charcoal back to 
a fine ash. If you are not ready to shut down for overnight burn when you next fuel the stove, load the 
stove with only one piece of wood and lay it across the firebox on top of the charcoal. Open the air control 
wide open and you will find the charcoal will burn down with the one piece of wood. Repeat the process 
until the ash level is significantly reduced.  

Troubleshooting

(Continued)

1.

 

Subject to clauses 2 & 3 of this Warranty, A.F. Gason Pty Ltd ACN  004 667 556 (Gason warrants the follow components of its heaters against defects in workmanship
 and/or materials for the following periods from the date of purchase: 

a)

 

the  rebox for ten years; 

b)

 

the paint  nish for a period of twelve months if the Purchaser has followed the instructions provided by Gason in the Operation and Installation Instructions manual; and 

c)

 

all other components for twelve months execpt the glass,  re brick lining or ba e plate if, in the opinion of Gason, these items have been damaged by impact. 

2.

 

This extended warranty does not apply; 

a)

 

if the heater is purchased from a person who has not been authorised by Gason to sell its products; 

b)

 

if, in the opinion of Gason, the heater or any other component has been subject to abuse, misuse, alteration, modi cation or has  not been installed, operated or maintained in 
 accordance with the instructions provided by Gason;  or, 

c)

 

to owners other then the original Purchaser. 

3.

 

If you believe that the heater you purchased contains a manufacturing defect and you wish to make a claim under this Warranty, please contact an authorised Gason service   
centre to arrange for an assessment. 

4.

 

If, after assessing the heater, Gason determines that the heater contains a manufacturing fault, Gason may at its discretion:  

a)

 

replace the heater; 

b)

 

repair or replace speci c components of the heater; or 

c)

 

provide a full refund. 

5.

 

Parts replaced under warranty are warranted for the balance of their original warranty period.  

6.

 

If, at the discretion of Gason, the heater or any part needs to be replaced, serviced or repaired at an authorised Gason service centre, then the person claiming under this  
Warranty must pay all costs associated with: 

a)

 

returning the heater; and 

b)

 

the delivery or collection of any new or repaired heater. 
Our goods come with guarantees that cannot be excluded under the Australian Consumer Law. You are entitled to a replacement or refund for a major failure and for 
compensation for any other reasonably foreseeable loss or damage. You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality  
and the failure does not amount to a major failure. 
Any bene ts you receive under these warranties are in addition to other rights and remedies that you may have as a consumer under a law in relation to the heater to which   
these warranties relate. 

These warranties are given by: 
A.F. Gason Pty. Ltd. 
Blake Street 
Ararat VIC 3377 
Please contact us if you have any queries on: 
Phone:   03  53522151 
or email us via the “Contact Us” section of our website:   www.gason.com.au

Содержание Riverina SRS3 Insert

Страница 1: ...nd c all other components for twelve months execpt the glass re brick lining or ba e plate if in the opinion of Gason these items have been damaged by impact 2 This extended warranty does not apply a if the heater is purchased from a person who has not been authorised by Gason to sell its products b if in the opinion of Gason the heater or any other component has been subject to abuse misuse alter...

Страница 2: ...wing machine oil on the shafts at the bearings Replace the fan in reverse to the removal Fan not working Check the power connection with another appliance If the power point is O K assume the Fan or the Switch is defective Isolate the power as above Check that the terminals on the loom and the switch are firmly connected If the fan then fails to function remove the fan and switch by firstly removi...

Страница 3: ... that the brush will go further down the chimney till it reaches the bottom The soot and creosote will fall down the chimney and into the firebox Clean residue from firebox Replace the baffle plate Make sure you do the job well The cleaner the flue the less chance there will be of the creosote sticking again After you have replaced the cowl inspect the roof flashing for any damage that may have be...

Страница 4: ...he only time you can leave the door open is on initial lighting or when reloading the heater Care of your glass If you are burning good dry wood you will have very little discolouration of your glass in normal burning cycle If you aim for an eight to ten hour overnight burn you should not get much discolouration You can control this by adjusting the air control moving from the left and slowly cree...

Страница 5: ...thod against the back wall of the firebox Now place one extra whole firebrick on either side of the firebox to complete the installation of the firebricks i e two each side and remainder on the back wall Push each brick and C frame firmly against the wall of the firebox and you are ready to light your fire Placement of firebricks in firebox Select the position that you wish to install your ZCB car...

Страница 6: ...earth Depth raised by X Y 890mm Table 1 Appliance height vs hearth requirements X Y When appliance is raised 155mm or more above floor level a 300mm non combustible hearth or floor protector is always required as per AS NZS 2018 2001 If the appliance is installed onto an existing step fireplace which projects in front of the appliance s fascia less than required corresponding height of step firepl...

Отзывы: