Technical documents
Troubleshooting
Observations
Possible cause
Remedies
No lighting up
- Batteries
- Gas income
- Communication
- Blocking of electronic box
- Connection
- Pilot
- Replace the batteries of the electronic
box and/or of the remote control
- Check the opening of the valve
- Purge the duct
- Reset the remote control (point 3,
chapter user)
- Push on Reset
- Wait for the cooling
- Replace the box
- Check the connection of the cables
- Check ignition (intensity and position)
- Check piezo wiring
- Replace the pilot
Lighting of the pilot
but no of the burners
- Pilot
- Check the intensity of the flame
- Check if obstruction of the pilot
- Check thermocouple
- Check gas pressure
- Check type of gas
Very low, blue and/or
agitated flames
- Gas flow
- Chimney setting
- Vermiculite
- Sealing
- Check gas type and pressure
- Check injectors diameter
- Check chimney's setting (draft
reduction)
- Check vermiculite quantity in burners
trays
- Clean burners
- Check the sealing of the door and of
different access hatches of the insert
Very high, very
yellow and/or
transparent flames
- Gas flow
- Chimney setting
- Vermiculite
- Logs
- Check gas type and pressure
- Check injectors diameter
- Check chimney's setting (draft
reduction)
- Check vermiculite quantity in burners
trays
- Clean burners
- Check logs positions