Jidé s.a. – Rue des Meuneries 11 – B-4650 HERVE (Belgique) – Tél. +32 87 31.75.12 – Fax +32 87 31.75.11 –
CARINO (EN) February 2020
29
Checks and first lighting
Before ending the complete installation of the fireplace, we recommend to check the sealing and
the connections of the different components.
-
Gas sealing
Sealing must be checked for the complete circuit of gas income to the valve, by a certified installer
or certified control organism.
A test with a leak detector or soap water must also be done to the connection of the suppling flexible
and the connection to the valve (do not forget to open previously the gas income block valve!).
-
Connections of different components
Before placing the gas drawer back, check that each cable and circuit is well connected.
See pattern:
1x9V
4xAA