background image

JEVI A/S  |  GODTHÅBSVEJ 7  |  DK-7100 VEJLE  |  T: +45 75 83 02 11  |  F: +45 75 72 29 00  |  [email protected]  |  WWW.JEVI.DK

PAGE 1/2

DELTA FAN HEATER

DE

CE

M

BE

R 2

01

7

DELTA is a robust, reliable fan heater that is designed for use in 
areas that require a little more of materials and performance, for 
instance construction sites and ships.
DELTA is also used for more permanent installations such as in-
dustrial buildings and warehouses, workshops, factories or ga-
rages, as it can go from transportable to permanent fixture with  
a simple wall-bracket.

It comes with an integrated 0-40°C thermostat that ensures op-
timal operation and minimizes energy consumption, as well as a 
thermal cutout function to protect against overheating. 

DELTA is built with internal casing in the heating chamber, which 
ensures that the entire flow of air passes over the heating ele-
ments. This eliminates problems with varying airflow and cold 
spots. 

The DELTA fan heater comes in two sizes:
•  TP1 = 3-9 kW - small cabinet
•  TP2 = 15-21 kW - large cabinet

SURFACE TREATMENT

DELTA is made of electro galvanized sheet metal which is sur-
face-treated with a 20 my powder coating in RAL colour 7004 
(light grey). In larger numbers, the fan heaters can be supplied 
in other colors or coatings.

TECHNICAL DATA

Voltage range:

•  1x110V to PE

Frequenzy, can be used at:

•  50 Hz and 60 Hz

Degree of protection for electrical components:

•  TP1: 3-9kW = IP44
•  TP2: 15-21kW = IP34

Temperature control:

•  TP1: Combi termostat with adjustable room thermostat 0-40°C 
  + manual 165°C thermo cut out (TSHH)
•  TP2: Adjustable room thermostat 0-40°C + automatic reset  
  125°C (TSH) + manual reset 160°C (TSHH)

Level regulation:

Manually operated 5-level change-over switch that regulates air 
speed and heating effect. Moreover, all types can be supplied 
with a 24-hour timer. A DELTA fan heater with timer function 
switches on when the set time has elapsed.

ELECTRICAL INSTALLATION

Permanent installation must always be performed by an authori-
zed electrician in accordance with relevant laws and regulations.

Off

Fan on

Half fan and half heat effect

Full fan and half heat effect

Full fan and full heat effect

TP1: 372 mm

TP2: 462 mm

TP1: 300 mm

TP2: 360 mm

TP1: 435 mm

TP2: 540 mm

TP1: 420 mm

TP2: 510 mm

TP1: 322 mm

TP2: 392 mm

TP1: 410 mm

TP2: 505 mm