27
Flow Control
Flow control can prevent data loss from buffer overflow. When sending data, if
the receiving buffers are full, a “stop” signal can be sent to stop the data flow.
Once the buffers are empty, a “start” signal can be sent to re-start the flow.
Hardware flow control uses two wires to send start/stop signals.
The optional settings: [None]; [Hardware RTS/CTS].
VT-UTF8 Combo Key Support
Use this item to enable VT-UTF8 Combination Key Support for ANSI/VT100
terminals.
The optional settings: [Disabled]; [Enabled].
Recorder Mode
With this mode enable only text will be sent. This is to capture Terminal data.
The optional settings: [Disabled]; [Enabled].
Resolution 100x31
Use this item to enable or disable extended terminal resolution.
The optional settings: [Disabled]; [Enabled].
Legacy OS Redirection Resolution
On Legacy OS, the Number of Rows and Columns supported redirection.
The optional settings: [80x24]; [80x25].
Putty KeyPad
Use this item to select FunctionKey and KeyPad on Putty.
The optional settings: [VT100]; [LINUX]; [XTERMR6]; [SCO]; [ESCN]; [VT400].
Redirection After BIOS POST
The settings specify if BootLoader is selected then Legacy console redirection is
disabled before booting to Legacy OS. Default value is Always Enable wich
means Legacy Console Redirection is enabled for Legacy OS.
The optional settings: [Always Enable]; [BootLoader].
Serial Port for Out-of-Band Management/
Windows Emergency Management Services (EMS)
Console Redirection
The optional settings: [Disabled]; [Enabled]. When set as [Enabled], the following
sub-items shall appear:
Console Redirection Settings
The settings specify how the host computer and the remote computer (which the
user is using) will exchange data. Both computers should have the same or
compatible settings.
Press [Enter] to make settings for the following items:
Out-of-Band Mgmt Port
The default setting is are: [COM1].
Terminal Type
The optional settings: [VT100]; [VT100+]; [VT-UTF8]; [ANSI].
Emulation: VT100: ASCII char set; VT100+: Extends VT100 to support color,
function keys, etc.; VT-UTF8: Uses UTF8 encoding to map Unicode chars onto
1 or more bytes; ANSI: Extended ASCII char set.
VT-UTF8 is the preferred terminal type for out-of-band management. The next
best choice is VT100+ and them VT100.
Bits per second
Содержание HPC-185SC-HD1900B Series
Страница 1: ...Panel PC User s Manual NO G03 PCNC7ARHD F Manual Revision 4 0 Release Date October 29 2019 ...
Страница 13: ...9 Product Dimension for HPC150GR HD1900B Series Measure Unit mm ...
Страница 14: ...10 Product Dimension for HPC170GR HD1900B Series Measure Unit mm ...
Страница 15: ...11 Product Dimension for HPC 185SC HD1900B Series Measure Unit mm ...
Страница 44: ...40 ...