background image

MJet V3

 

Product model/type: MJet V3 2017-SW > 3.0

MJet V3 USER'S GUIDE AND SAFETY MANUAL 

Содержание MJet V3

Страница 1: ...MJet V3 Product model type MJet V3 2017 SW 3 0 MJet V3 USER S GUIDE AND SAFETY MANUAL...

Страница 2: ...rm or by any means including photocopying recording or other electronic or mechanical methods without the prior written permission of the publisher For permission requests write to the publisher addre...

Страница 3: ...safety information on this page and note specific safety requirements as explained by procedures in this manual Failure to follow these instructions could result in serious personal injury or death 3...

Страница 4: ...echnical information 2 6 Safe operating practices 3 7 Unpacking the box 4 8 Set up the blower 5 8 Crash test 6 10 Blower operations 7 11 Maintenance 8 12 Troubleshooting guide 9 13 EC Declaration of c...

Страница 5: ...t the exit of the air block preventing movement in any direction Seals conform around the pipe when clamped The fiber optic cable is fed through the pipe by a combined pulling pushing force The pullin...

Страница 6: ...eed 120 m min maximum 3 Cable sizes 4 40 mm 4 Pipe sizes 10 63 mm D Electrical requirements 1 Power requirements 9V alkaline battery 2 Power connection Battery compartment E Physical specifications 1...

Страница 7: ...per control 9 Keep hands away from belt drive while blower is in operation B Pneumatic devices The MJet V3 is a pneumatic device using pressurized air to project cable at high velocities Please observ...

Страница 8: ...entation of seal on fiber is correct so that it will seat in the air block properly The seal lip of the cable seal should be facing the pipe end Once the cable seal is positioned properly on the cable...

Страница 9: ...is off before connecting the air hose Attach the air compressor hose to the air compressor Then connect the compressor hose to the blower unit The unit uses a Camlock coupling an adaptor from Camclock...

Страница 10: ...est possible setting that will allow for a desirable installation speed 1 Insert the cable and seal inside the pipe pack as it would be for the actual installation 2 Install a 1 to 2m test length of p...

Страница 11: ...block Do not apply maximum air pressure and flow at initial air engagement Do not open air supply before adequate fiber has been pushed in 100M IMPORTANT Do not exceed 16 bars when operating the unit...

Страница 12: ...ed and in working order it will dispense 3 drops min otherwise adjust it by turning it to the correct amount Do not run engines with empty or defect oil dispenser How to Turn off the machine Make sure...

Страница 13: ...er or the measurement on the cable determine where the blockage might be located 4 Notify supervisor about problem and determine a solution accordingly Belt feed does not pull the cable 1 Assist the r...

Страница 14: ...14 10 EC Declaration of conformity H kan Johansson...

Страница 15: ...15 11 Notes...

Страница 16: ...MJet V3 USER S GUIDE AND SAFETY MANUAL Version 2021 10...

Отзывы: