Jetter AG
55
JVM-507B
Initial commissioning
Preparatory work for initial commissioning
The JVM-507B in delivered condition has got IP address 192.168.10.15.
Configure the Ethernet interface of your PC so that it is able to communicate
with the JVM-507B via this IP address.
The JVM-507B only powers up if the supply vU BATT is applied to the
ignition (+).
To prevent the application program from being launched, press function keys
F1 and F3 simultaneously.
It may happen that the device does not react after power-up. This condition,
however, lets you access the device using FTP or JetSym.
The default application program launched on the JVM-507B after power-up
displays the following input mask on the display.
The node ID displayed is the address of the first CAN interface set in the
JVM-507B. This address can be set by using the function keys F7 and F8.
Function key F7 increases the address in steps of 1. Function key F8
decreases the address in steps of 1.
The IP address, MAC address and OS version are also displayed.
Establishing an Ethernet
connection
Requirement for
power-up
Skipping the application
program during
power-up
Default display
Содержание JVM-507B - HMI
Страница 1: ...User Manual JVM 507B HMI 60881526 We automate your success...
Страница 8: ......
Страница 12: ......
Страница 52: ......
Страница 70: ...70 Jetter AG 6 Initial commissioning Initial commissioning in JetViewSoft see page 58 Related topics...
Страница 78: ......
Страница 88: ......
Страница 99: ...Jetter AG 99 JVM 507B Programming If Merker1 Then Inc Status_LEDs Delay T 100ms End_If End_Loop End_Task...
Страница 106: ......
Страница 128: ......
Страница 146: ...146 Jetter AG Appendix The JVM 507B is intended for installation in the driver s cabin Installation location...
Страница 151: ......