7 Description of Connections
58
Jetter AG
For connection with motor holding brake
Dimensions of the motor mating connector are specified in millimeters.
Motor Power Cable KAY_0624_xxxx
Terminals of the
JetMove 105
Shield
Mating
connector of the
motor (female,
solder side)
7 x 1.0 mm
2
Shielded, highly
flexible 6-wire
cable with PE.
The wires are
equipped with wire
end ferrules.
Connect both sides of the shield with
the greatest possible surface area!
Use metallized housing only!
Pin
Wire Number
Signal
Pin
X1.U2
1
Phase 1
1
X1.V2
2
Phase 2
5
X1.W2
3
Phase 3
2
X1.PE
Yellow-green
PE conductor
X62.2
5
Brake +
6
X62.1
4
Brake -
4
mating
connector
solder side
solder side
18
26
65
5
2
4
6