7 Description of Connections
50
Jetter AG
7.2
Power Supply
Specification of Terminal X1
• 8-pin screw clamping terminal (type MC 1.5/ 8-ST-3.5)
• Diameter of the cable apt for connecting: 0.14 - 1.5 mm
2
with bootlace ferrules and plastic sleeve: 0.25 - 1 mm
2
• Bladed screw-driver: 0.4 x 2.5 mm
• Stud torque for the screw clamping terminal: 0.22 Nm
Specifications of Connecting Cable
• Cable size: 2 * 1.0 mm² for the motor power supply
• Cable size: 1 * 0.5 mm² for the logic power supply
• Material: Copper
• Temperature class: 60 °C
• Stripping length of cores: 6 mm
• Shielding not required
Power Supply
Terminals X1 on the
amplifier side
Signal
Specification
PE
PE conductor
The PE conductor is connected to
the enclosure.
+V
MOT
DC link supply
24 / 48 V DC (12 ... 48 V DC)
I
max.
= 27.5 A
No inrush current limitation
+V
LOG
Power supply of
the logic unit
24 V DC (12 .. 30 V)
I
max.
= 250 mA at 24 V
No inrush current limitation
0V
Zero potential
for the power
supply
Ground reference for +V
MOT
and
+V
LOG
Содержание JM-105
Страница 1: ...User Manual JM 105 Digital Servo Amplifier 60872838 We automate your success...
Страница 10: ...Table of Contents JetWeb 10 Jetter AG...
Страница 21: ...JetMove 105 2 2 Mechanical Installation Jetter AG 21 Fig 3 Recommended mounting m i n 2 5 m m...
Страница 26: ...2 Installing the JetMove 105 26 Jetter AG...
Страница 32: ...3 Operating Conditions 32 Jetter AG...
Страница 34: ...4 Physical Dimensions 34 Jetter AG...
Страница 40: ...5 Technical Specifications 40 Jetter AG...
Страница 84: ...7 Description of Connections 84 Jetter AG...
Страница 96: ...11 Ordering Information 96 Jetter AG...
Страница 97: ...JetMove 105 Appendices Jetter AG 97 Appendices...
Страница 98: ...Appendices 98 Jetter AG...