JetMove 208-480
Jetter AG
77
8
Status Monitoring
The output stage LEDs indicate the operating status of the digital servo amplifier.
JetMove 208-480 - LEDs
LED
Color
Description
5 V
Green
Logic voltage is ok
L1
Yellow
Axis is standing still (speed = 0)
L2
Yellow
A voltage of 24 V is applied to the input of
the positive limit switch (LIMIT+).
L3
Yellow
A voltage of 24 V is applied to the input of
the negative limit switch (LIMIT-).
INFO
The seven-segment display of the output stage indicates the operating and fault
conditions of the digital servo amplifier. The various display modes are set by the
Motion Setup. Mode 0 (default) is used for normal operation and mode 1 for
commissioning.
5 V
L 2
L 3
L 1
JetMove 208-480 - Seven-Segment Display
Mode 0: Normal Operation
Value
State
Description
0
NOT READY TO BE
SWITCHED ON
Initialization of amplifier functions
1
SWITCH-ON INHIBIT
Initialization completed. Safe state
achieved after initialization and
acknowledgement of errors.
The drive controller can be switched
on.
2
READY TO BE SWITCHED
ON
Drive controller has been disabled by
software command.
The drive controller can be switched
on.
3
SWITCHED ON
DC link monitoring is activated.
4
OPERATION_ENABLED
The drive controller is enabled.
7
QUICK STOP ACTIVATED
A quick stop has been activated.
The drive was decelerated to zero
speed and then locked.
Содержание JetMove 208-480
Страница 1: ...User Manual JM 208 480 Digital Servo Amplifier 60870619 We automate your success...
Страница 10: ...Table of Contents 10 Jetter AG...
Страница 20: ...1 Safety Instructions 20 Jetter AG Fig 2 Shielding of SUB D connectors in conformity with the EMC standards...
Страница 22: ...1 Safety Instructions 22 Jetter AG...
Страница 34: ...3 Operating Conditions 34 Jetter AG...
Страница 36: ...4 Physical Dimensions 36 Jetter AG...
Страница 44: ...5 Technical Data 44 Jetter AG Therefore wait until the motor is cold before enabling the axis again...
Страница 46: ...5 Technical Data 46 Jetter AG...
Страница 90: ...10 Connection Diagrams 88 Jetter AG...
Страница 100: ...13 Safe Torque OFF STO Option S1 98 Jetter AG...
Страница 110: ...15 Ordering Information 108 Jetter AG...
Страница 112: ...Appendices 110 Jetter AG...
Страница 113: ...JetMove 208 480 Appendices Jetter AG 111 Appendices...
Страница 114: ...Appendices 112 Jetter AG...
Страница 122: ...Appendices 120 Jetter AG...
Страница 123: ...JetMove 208 480 Appendices Jetter AG 121...