7 Description of Connections
72
Jetter AG
7.7
Digital Inputs, Logic Power Supply
Specification of Terminal X10
• 10-pin spring tension terminal (type ZEC 1,0/10-ST-3,5)
• Cross-sectional area of the connecting cable: 0.2 ... 1 mm
2
(AWG 24 ... AWG 16)
with bootlace ferrules in a plastic sleeve: 0.25 ... 0.75 mm
2
(AWG 24 ... AWG 18)
• Bladed screw-driver: 0.4 x 2.5 mm
Digital Inputs, Logic Power Supply
Wiring
Terminal
X10
Signal
Description
Specifications
ENABLE
Hardware
enable for
the power
supply of the
motor (input)
• A high signal at this
input is necessary for
the motor to be supplied
(the power supply has to
be connected before
software enable).
• A low signal de-
energizes the motor
immediately.
• DC 24 V
• 7.5 mA max.
• Operating point:
< 6 V low, > 15 V
high
REF
Reference
switch (input)
• Depending on the
parameter setting, this
input is used for
referencing.
• DC 24 V
• 7.5 mA max.
• Operating point:
< 6 V low, > 15 V
high
NC or NO contact
LIMIT +
Positive limit
switch (input)
• Depending on the
parameter setting, this
input is used as a
positive limit switch.
• DC 24 V
• 7.5 mA max.
• Operating point:
< 6 V low, > 15 V
high
NC or NO contact
NC contact
recommended
LIMIT -
Negative
limit switch
(input)
• Depending on the
parameter setting, this
input is used as a
negative limit switch.
• DC 24 V
• 7.5 mA max.
• Operating point:
< 6 V low, > 15 V
high
NC or NO contact
NC contact
recommended
Содержание JetMove 208-480
Страница 1: ...User Manual JM 208 480 Digital Servo Amplifier 60870619 We automate your success...
Страница 10: ...Table of Contents 10 Jetter AG...
Страница 20: ...1 Safety Instructions 20 Jetter AG Fig 2 Shielding of SUB D connectors in conformity with the EMC standards...
Страница 22: ...1 Safety Instructions 22 Jetter AG...
Страница 34: ...3 Operating Conditions 34 Jetter AG...
Страница 36: ...4 Physical Dimensions 36 Jetter AG...
Страница 44: ...5 Technical Data 44 Jetter AG Therefore wait until the motor is cold before enabling the axis again...
Страница 46: ...5 Technical Data 46 Jetter AG...
Страница 90: ...10 Connection Diagrams 88 Jetter AG...
Страница 100: ...13 Safe Torque OFF STO Option S1 98 Jetter AG...
Страница 110: ...15 Ordering Information 108 Jetter AG...
Страница 112: ...Appendices 110 Jetter AG...
Страница 113: ...JetMove 208 480 Appendices Jetter AG 111 Appendices...
Страница 114: ...Appendices 112 Jetter AG...
Страница 122: ...Appendices 120 Jetter AG...
Страница 123: ...JetMove 208 480 Appendices Jetter AG 121...