478
Jetter AG
10 Programming
Configuring the interface
Module registers MR 1 through MR 6 are used to configure the
user-programmable serial interface.
This guide proceeds from the assumption that wiring between controller and
remote device is according to the standard of the selected interface.
To configure the user-programmable serial interface proceed as follows:
Step
Action
1
Enter value 1 into MR 2.
2
Enter the desired communication parameters into MR 2 through MR 6.
Result:
The serial interface is set as user-programmable interface. Both the
transmit buffer and receive buffer are cleared.
Introduction
Prerequisites
Configuring the interface
Содержание JC-120MC
Страница 1: ...User Manual JC 120MC Controller 60880901 We automate your success...
Страница 18: ......
Страница 40: ...40 Jetter AG 3 Identifying Hardware revisions see page 38 Related topics...
Страница 160: ......
Страница 186: ......
Страница 196: ......
Страница 395: ...Jetter AG 395 JC 120MC Programming Result When initializing the JX2 system bus the adjusted baud rate values were used...
Страница 485: ...Jetter AG 485 JC 120MC Programming Topic Page Programming 486 Registers 498 Contents...
Страница 521: ...Jetter AG 521 JC 120MC Programming Use 29 bit identifier Default 11 bit identifier...
Страница 586: ......
Страница 604: ......
Страница 633: ......