10 Programming
Supported commands - Class 2
force multiple coils
Enabling/disabling several outputs
The output number within the JC-120MC is calculated as follows: Output
number specified in the command plus the content of register 272705
Output
Offset
.
read/write registers
Reading/writing registers simultaneously
The starting register number within the JC-120MC is calculated as follows:
Register number specified in the command plus the content of R 272702
Register Offset
.
fc 15