426
Jetter AG
10 Programming
Section [SMTP]
This section lets you specify the parameters for establishing a connection with
the SMTP server.
[SMTP]
IP = 192.168.40.1
PORT = 25000
HELO = JetControl_2
USER = JetControl0815
PASSWORD = MyPassWord
This type of authentication requires the JC-120MC to log on at the SMTP
server before sending an e-mail. During the logon process USER and
PASSWORD must be entered. The JC-120MC supports the following
authentication procedures:
LOG-ON
PLAIN
CRAM-MD5
IP
In the given example
192.168.40.1
Description
IP address of the SMTP server;
can also be specified as name.
Allowed values
> 1.0.0.0
< 223.255.255.255
Illegal values
Network address
Broadcast address
In case of illegal value or
missing entry
The e-mail feature is not available
PORT
In the given example
25.000
Description
Port number of the SMTP server
Allowed values
> 0
< 65.536
Illegal values
> 65,335
In case of missing entry
25
Introduction
Example:
Authentication
Configuration values
Содержание JC-120MC
Страница 1: ...User Manual JC 120MC Controller 60880901 We automate your success...
Страница 18: ......
Страница 40: ...40 Jetter AG 3 Identifying Hardware revisions see page 38 Related topics...
Страница 160: ......
Страница 186: ......
Страница 196: ......
Страница 395: ...Jetter AG 395 JC 120MC Programming Result When initializing the JX2 system bus the adjusted baud rate values were used...
Страница 485: ...Jetter AG 485 JC 120MC Programming Topic Page Programming 486 Registers 498 Contents...
Страница 521: ...Jetter AG 521 JC 120MC Programming Use 29 bit identifier Default 11 bit identifier...
Страница 586: ......
Страница 604: ......
Страница 633: ......