Jetter EBELT BEST Series Скачать руководство пользователя страница 1

OPERATING PANELS

BEST

PROGRAMMING Manual

EBELT OPERATING PANELS

BEST 240-0

BEST 240-8

BEST 224-12-Z

BEST 240-24-Z

BEST 240-48-Z

BEST240LCD-8

BEST 240LCD-12-Z

BEST 240LCD48-Z

Jetter AG  Gräterstr.2  D-71642 Ludwigsburg                                                    Tel:  +(49) 7141 / 2550-0
Errors and omissions  excepted                                                                          Fax: +(49) 7141 / 2550-566
                                                                                                                            Internet: http://www.jetter.de

                                                                                                                            Art.Nr. 60866665

Содержание EBELT BEST Series

Страница 1: ...EST 240 0 BEST 240 8 BEST 224 12 Z BEST 240 24 Z BEST 240 48 Z BEST240LCD 8 BEST 240LCD 12 Z BEST 240LCD48 Z Jetter AG Gr terstr 2 D 71642 Ludwigsburg Tel 49 7141 2550 0 Errors and omissions excepted...

Страница 2: ...es 4 1 1 Suppression of Leading Zeros 4 2 Input Variables 4 2 1 Indexed Variable Address 4 3 Input Limits 4 3 1 Indexed Input Limits 4 4 Variable Formats 4 4 1 Variable Format UNS 4 4 2 Variable Forma...

Страница 3: ...between 8 Kbytes EEPROM and 512 Kbytes Flash EPROM 1 Loadable Character Generator In addition to the internal character generator the BEST operating panels with LED text display allow loading of a sec...

Страница 4: ...first internal character set is loaded in accordance with the character table used with the IBM PC Scrollzeit 3 2 4 When a message with more than 2 lines is programmed and to be displayed on a 2 line...

Страница 5: ...ting the Enter key info text The structure of a message can be visualized as consisting of four sections Example Section 1 Variable definition 2 Section 2 Display message image Section 3 F key reset S...

Страница 6: ...programmed in a message The lines are displayed in such a way that the input cursor is visible An input variable must therefore be inserted in at least every second line If scaled variables are used...

Страница 7: ...upt an ongoing input process This means that after the info key is released the input cursor is in the previous position It is not possible to display variables in the info text Except for the identif...

Страница 8: ...Indication Variables Indication variables allow suppression of leading zeros for the following variable formats UNS BCD BCDL The character is replaced by a Example 4 2 Input Variables If limit values...

Страница 9: ...ther messages may still contain the full 8 variables 4 4 Variable Formats The representation format of a variable is specified as part of the variable definition This manual describes all of the forma...

Страница 10: ...as a 4 digit HEX number in the range of 0 FFFF The number of filler characters must be between 1 and 4 The keys 0 and 9 are accepted by the input editor The characters A F are produced by simultaneou...

Страница 11: ...specified in the system set up will be used IBM CPM If the filler characters are assigned to the second graphics character set the characters defined there will be displayed Only displayable character...

Страница 12: ...Editon 2 94 If the variable format TXT is to be used as indication variable a min limit must be specified after the character in order to identify the starting point in the text memory Example 4 5 Sca...

Страница 13: ...is read from register 25 The scaling range is specified next When selecting the range for a scaled display it must be taken into consideration that the number of measuring points cannot be increased...

Страница 14: ...limit The variable is inserted in place of the first filler character the limit value is inserted in place of next filler characters If the BCDL LNG format or IL MD format 2 data words is used at lea...

Страница 15: ...are required to represent the message number 1008 The selected message image does not contain a text string The variable field contains 4 filler characters 1009 A syntax error has been detected in the...

Страница 16: ...display is therefore not possible This message is only required for PLC connections which are provided with an integrated interface switch in place of the PG MUX 1023 This message is displayed if the...

Страница 17: ...ntrol sequences may need to be inserted into the text bold print form feed cut instruction etc to allow printer control we have provided appropriate options The text is printed as follows The characte...

Страница 18: ...een 20h and 9Fh are permitted The characters from 20h to 7Fh can be used as reference characters for the second character set The user defined characters of the 2nd character set are printed in the IB...