Sensor MUI EX

  

-1- 

 

Assignment of the MUI sensor is measurement of voltage, current and consumed capacity of flight 

batteries in the model. The wireless data transmission by the DUPLEX 2,4GHz system is monitored by 
the JETIBOX terminal.   
 

For communication purposes the Duplex system takes advantage of the 2,4 GHz band, which besides 

sending  remote  control  data  to  the  model  also  receives  data  from  the  model  back  to  the  transmitter. 
During flight obtained telemetric data are transmitted in real time and the actual values of the measured 
data  can  be  displayed  on  the  JETIBOX  LCD.  Telemetric  MUI  sensors  execute  voltage  and  current 
measurements  in  your  model  and  transmit  these  informations  with  the  aid  of  the  DUPLEX  system 
(receivers  and  transmitter  modules).  Thanks  to  exact  current  measurements  these  sensors  render  it 
possible to trace the spent capacity of the measured battery. The MUI unit is recording the spent current 
flow time and its average as well as maximum value. Furthermore it offers exact voltage measurements 
and recordings of voltage minimum and maximum values.  
The task of parameter adjustment and measured data setup is performed by the well known alround talent 
– the JETIBOX terminal. 
 

MUI sensors allow setting of acoustical signals in order to announce violation of set parameters. Such 

alarms  may  be  set  for  measurements  of  maximum  current  and  minimum  voltage  as  well  as  for  a 
maximum  of  consumed  battery  capacity.  The  sound  signal  is  generated  by  a  siren  integrated  in  the 
transmitter module. For better differentiation are the particular alarms distinguished by Morse alphabetic 
letters. The acoustical alarm generation in case of parameter violation is working even if the JETIBOX is 
not connected. With the JETIBOX in place the LCD display shows which parameter has been violated. In 
case of violation of several parameters the alerts alter consecutively as well as the indications on the LCD 
display.   
 

Technické parametry 

MUI 30 

MUI 50 

MUI 75 

MUI 150 

MUI200 

Dimensions [mm]

 

20 x 16,5 x 5   27 x 19 x 11  

27 x 19 x 11  

27 x 19 x 11  

27x19x11 

Weight

 

10 g 

19 g 

21 g 

25 g 

30g 

Range of measured voltage

 

0 – 60 V 
0 – 60 V 
0 – 60 V 
0 – 60 V 

0 - 60V 

Range of measured current

 

0 – 30 A 

0 – 50 A 

0 – 75 A 

0 – 150 A 

0 – 200 A 

Accuracy of voltage 
measurment

 

0,1 % 

Accuracy of current 
measurment

 

1 % 

Operation temperature

 

- 10 to + 85° C 
- 10 to + 85° C 
- 10 to + 85° C 
- 10 to + 85° C 

-10 to + 85°C 

Supply voltage

 

5 – 8,4V 
5 – 8,4V 
5 – 8,4V 
5 – 8,4V 

5-8,4V 

Sensor internal consumption

 

24 mA 

32 mA 

32 mA 

32 mA 

32mA 

 

Menu of the telemetric MUI Sensor 

Take advantage of the JETIBOX for parameter adjustment and data readout. After connection to the MUI 
sensor the sensor identification is shown and in the second line the preadjusted actual measured data. By 
long pushing down button R (right) a fast deletion of all measured parameters can be triggered (min. and 
max. voltage, max. current, average current, runtime, capacity). Fast deletion is indicated in the first line 
of the display by an asterix „*“. 
 
By pushing the push button D (downward arrow) of the JETIBOX you will enter the MUI sensor menu.  
 

MUI  MENU: 

Actual  Value

  – 

by  pushing

 

D  (downward  arrow)  you  will  select  the  display  of  actual 

measured values  

Volt  /  Current  –

  displays  actual  measured  voltage  and  the  current  passing  through  the  sensor.  By 

simultaneously pushing arrows R and L (right and left) the zero value of the sensor current is calibrated. 
To the actual measured current value the zero current display is added, i. e. the so called zero shift.    

Capacity

 – shows the actual consumed capacity 

Run Time

 – shows the total time of current passage through the sensor. Included is also the time when the 

current has exceeded the adjusted current value 

Start Trigger 

in the

 Setting menu.

  

 