background image

Model: HALFGEN (X)

Important: 

 Read these warnings and instructions for use carefully to familiarize 

yourself with the appliance before connecting it to its gas container. Keep these 

instructions for future reference. 

USE OUTDOORS ONLY  

(EN) ENGLISH

Do not store or use gasoline or other 

liquids with flammable vapors in the 

vicinity of this or any other appliance.

DANGER

FOR YOUR SAFETY

CARBON MONOXIDE HAZARD

This appliance can produce carbon monoxide which 

has no odor. 
Using it in an enclosed space can kill you. 
Never use this appliance in an enclosed space such as a 

camper, tent, car, or home. 

Jetboil  |  Johnson Outdoors Gear, Inc.

540 N. Commercial St., Manchester, NH 03101
T: 1-603-518-1600 / 1-888-611-9905
F: 1-603-518-1619

Visit 

www.jetboil.com/wheretobuy

 

to locate a dealer near you

If there is a leak on your appliance (smell of gas), move it to a well-ventilated, flame-free location 

where the leak may be detected and stopped. Check for leaks on your appliance outside. Do not 

use a flame to detect leaks; use soapy water. ONLY USE IN WELL VENTILATED AREA. Accessible 
parts may become very hot.
 Keep young children away. Stove must be operated on a horizontal 

surface, at least 1m/3.3ft away from any combustible materials. Do not move, lift, or tilt stove with 
lit burner(s). 

Gas category: Propane under vapor pressure. This appliance should only be used with 16.4 oz 
disposable propane cylinders (sold separately). The LP-gas cylinder(s) used with this stove must 
be constructed and marked in accordance with the specifications for LP-gas cylinders of the U.S. 
Department of Transportation or Transport Canada, CAN/CSA B339. Refillable Bulk LP-Gas Tanks 

with a maximum capacity of 20 pounds may also be used with an optional bulk tank adapter hose 

(use Eureka! model 2572182 to connect to bulk tank). Jet Size: 0.39mm Gas Consumption: 10.4 
MJ/hr (AU) || 210 g/hr [2.9 kW] (EU) || 10,000 BTU/hr (CA)

SPECIFICATIONS

ASSEMBLY

Refer to the following diagrams shown on Page 1 when assembling and operating HalfGen:

1.

 

Fully Assembled Stove System

2.

 

Latched Stove

3. 

Burner Detail

4. 

Fuel Cylinder Attachment

5. 

Windscreen Attachment

6.

 

Grate End Removal

7. 

Grate Tab Removal

8. 

Burner Removal

9. 

Drip Tray Removal

10. 

Packing Order

11. 

Proper Electrode Positioning

Remove Packed Contents from Bag (10).  Place latched Stove (2) on a flat, level surface, and then 
gently pull the two rubber latches (2.1) free from latch hub (2.2).  Remove the 9” FryPan (1.2) and 
set to the side.  Ensure that the control valve (3.1) is closed firmly (rotate clockwise).  Securely 
screw Fuel Regulator (4.1) to the Fuel Input port (4.2) located on the back left of the Stove.  
Securely screw Propane Cylinder (4.3) into Fuel Regulator, in the orientation shown in (4). Never 
operate stove with Propane Cylinder in an inverted position.  To attach Windscreen (1.3), align the 
large opening in the Windscreen arms over the three Feet (5.1) located on the bottom of the stove, 
and pull outward until the smaller opening (5.2) slides into the slots (5.3) on each of the three Feet.  
Prior to initial use, remove plastic backing on both sides of Windscreen.  

OPERATION WARNINGS

Do not leave stove unattended while in use. Keep stove area clear and free from combustible 

materials, gasoline, and other flammable vapors and liquids.  Do not obstruct the flow of 

combustion and ventilation air to the stove. Check the seals before connecting a new gas container 
to the appliance. 

The gas container/canister shall be changed in a well ventilated location, 

preferably outside, away from any sources of ignition, such as naked flames, pilots, electric 
fires, and away from other people.

 If there is a leak on your appliance (smell of gas), take it 

outside immediately into a well ventilated, flame free location where the leak may be detected and 

stopped. If you wish to check for leaks on your appliance, do it outside. Do not try to detect leaks 

using a flame, use soapy water. Put some soapy water on the gas connection points between gas 
cansister and the appliance, if bubbles are found, there is gas leakage. DO NOT fry or cook foods 
with low moisture content when using Jetboil 5L Flux Pot (sold separately). If heating liquids near 
maximum capacity, use only low flame settings and exercise caution to prevent boil-over. Ensure a 
1” minimum gap between Windscreen and any cookware used when Windscreen is attached. Use 
only windscreen provided with stove. Other windscreens can overheat the fuel cylinder. If you 

overheat the cylinder, it can explode.  

OPERATING INSTRUCTIONS

Ignite burners before placing cookware on grates.

 Keep burner at arm’s length, away from face, 

during ignition. Flame can erupt and flare during ignition. Never expose stove to flammable vapors 
or liquids while lighting the burner. It can cause an explosion or fire. The stove must not be 
exposed to flammable vapors or liquids during lighting. 
Lighting the Burner: Test igniter (3.2) before opening valve. If a spark is not observed between 
Electrode (3.3) and Burner (3.4), refer to maintenance section. To light, open control valve (3.1) 
counterclockwise until fully opened and gas flow can be heard, then flip igniter lever (3.2) until 
flame is observed. Do not move, lift, or tilt burner while lit. Fuel can spray and cause flare-ups. 
Cooking: Rotate control valve (3.1) clockwise to decrease flame setting. If using Jetboil 5L Flux Pot 
(sold separately), add liquid or liquid food to the pot before placing on burner - DO NOT HEAT 
EMPTY COOKING POT. 
Set 5L Flux Pot on center of cooking grate, bottom of the pot will center 
on the grate to maximize heating performance. 
Expanding your cooking system: This stove comes equipped with a Patent-Pending JetLink™ 
fuel output port (3.5), which provides regulated fuel to additional JetLink™-compatible stoves and 
accessories offered by Eureka! or Jetboil. The port is located on the side of the Stove. Refer to 
instructions accompanying JetLink™ accessories for their use. Do not attempt to use stoves or 
accessories that are not certified as JetLink™-compatible by Eureka! or Jetboil.
Cleaning Stove: Allow stove to cool before cleaning. Pinch tabs of Cooking Grate (6.1) together to 
release from Drip Tray (6.2) and Chassis (6.3). Lift up this end of Grate, and pull Tab (7) from under 
Drip Tray and Chassis. Set Grate aside. Un-screw Burner (8) by rotating counter-clockwise, taking 
caution not to bend the Electrode (3.3). Drip Tray (9) is now free to remove from Chassis. 
Cleaning Grate / Drip Tray / 9” Fry Pan:

 Do not use a dishwasher or abrasive compounds to 

clean. Only wash by hand with soapy water.

STORAGE AFTER USE

Turn off control valve (3.1) (tighten clockwise) to extinguish flame to burner. EXPOSED METAL 
PARTS MAY BE HOT. ALWAYS CHECK THAT THE BURNER IS EXTINGUISHED BEFORE 
DISCONNECTING THE FUEL CYLINDER.
 Disconnect Fuel Cylinder and then Fuel Regulator. 
Allow stove to cool, and store all components in Carry bag as shown (10). Always disconnect fuel 
cylinder from Regulator after use. 
Fuel cylinders can explode. Store fuel cylinders outdoors in a 

dry, well-ventilated area, away from heat, and out of reach of children. 

TROUBLESHOOTING AND MAINTENANCE

Do not modify this appliance. Modification of the product and/or using the product not in 
accordance with the instructions and recommended use may be hazardous and will void the 
warranty. This appliance must only be serviced by an authorized person. If an issue cannot be 
corrected using these instructions, see Limited Warranty below. Contact your local dealer, 

distributer, or Jetboil for parts and/or service. If stove is operating poorly, check mix tube to ensure 

that air holes are not blocked, and that the jet is not dirty or contaminated. Ensure that Fuel Input 
and JetLink™ Output ports are kept clean and debris-free at all times. If the stove flashes back to 

the burner tube or lift, turn off stove, call supplier.

Flame does not extinguish: Valve is damaged. Tighten valve as much as possible, blow out flame, 
and immediately detach fuel cartridge. Return to dealer. 
Igniter fails to spark:

 If igniter will not spark, check positioning of electrode in relation to burner 

(11). If not positioned as shown in instructions, re-position the electrode accordingly. If igniter still 

fails to spark, use matches or a lighter. See your dealer or contact Jetboil for service. If stove is wet, 

igniter may fail to spark.

WARRANTY INFORMATION

USA: Jetboil HalfGen has a 1-year limited warranty. Should this product not function properly 

under normal use within 1 year of purchase, contact the dealer or Jetboil for return process 
information. Jetboil alone will determine if the problem is covered by this warranty. If so, Jetboil 

will repair or replace the unit at its discretion and return it to you free of charge. This warranty 
does not cover any damage or malfunction arising from misuse, modification, improper 

maintenance, negligence, normal wear and tear, accident, or use other than as described in these 

instructions. This warranty applies only to the original purchaser. Proof of purchase is required. 
Except as provided herein, there are no other warranties, express or implied, including but not 
limited to the implied warranties of merchantability and fitness for a particular purpose. Jetboil 
shall not be liable for any consequential or incidental damages whatsoever. This warranty gives 
you specific legal rights. You may also have other rights that vary from state to state. Some states 
do not allow the exclusion or limitation of incidental or consequential damages, or limitation or 

exclusion of implied warranties, so the above exclusions or limitations may not apply to you. 

INTERNATIONAL: 

Contact your local retailer or distributor for information regarding any 

warranties covering your HalfGen. For a list of distributors, refer to the list provided elsewhere on 
this sheet, or visit jetboil.com. Do not modify the appliance. Modification of the product and/or 
using the product not in accordance with the instructions and recommended use may be hazardous 
and will void the warranty. HalfGen must only be serviced by an authorized person. Return to your 

local retailer or distributor if a fault cannot be corrected using these instructions.

ANSI Z21.72-2016 • CSA 11.2 – 2016

For additional diagrams and FAQs, visit: www.jetboil.com

1

4

2

3

5

6

7

8

9

10

11

V2

(EN) Instructions for use

(FR) Directives d’utilisation

(ES) Instrucciones de uso

           
FIRE OR EXPLOSION HAZARD
If you smell gas:
1. Do not attempt to light appliance. 
2. Extinguish any open flame.
3. Disconnect from fuel supply.
4. Evacuate immediately.
5. Allow gas to dissipate 5 minutes
    before relighting the appliance.
Failure to follow these instructions 
could result in fire or explosion, 
which could cause property damage,
personal injury, or death.

WARNING

Отзывы: