Lubrication 
Use transformer oil, Shell Tellus Turbo 
T or equal. The ball bearings are of the 
closed design and permanently greased.

Inspecting the Hydraulic Parts 
The pump housing (volute) and the 
impeller should be visually inspected 
every time an oil and stator inspection is 
made. Change parts if excessive wear 
has occurred or if performance of pump 
has been impaired.

Note: If impeller is worn and in need of 
replacing, always install new oil lip seals 
and, on models with a shaft sleeve a new 
shaft sleeve at the same time.

Inspecting Motor Cable 
Carefully inspect the outer shield and the 
wire endings. If the outer shield has been 
damaged, water can enter the pump 
through the core. The cable should 
never be stretched by force and the 
pump never lifted by the motor cable. 
This could severely damage the cable 
and the cable glands in the cable holder. 
Perform continuity test on each lead.

Detailed Overhaul 
A complete overhaul should be made 
if water has been detected in the stator 
housing, or if the pump has been in 
daily use for a year. The intervals can 
be increased if the pump has been 
permanently installed as a sump pump 
with automatic controls. Dismantle the 
pump completely, replace damaged 
or worn parts with new, original parts. 
Clean all surfaces and check for cracks 
or damage. If water is present in stator 
housing and/or in oil chamber, replace 
mechanical seals, O-rings, oil seal and 
bearings.

SUBMERSIBLE PUMP

OPERATOR’S MANUAL

CONTENTS PAGE
Start-up Description .........................2
Electrical Connection .......................2
Handling ...........................................2
Rotation of Impeller ..........................2
Placing Pump ...................................2
Liquid Temperature ..........................2
Submersion Depth ...........................2
Cold Weather ...................................2
Troubleshooting ...............................3

- 1. Not starting ...........................3
- 2. Low capacity or low head ....3
- 3. Water in stator housing ........3
- 4. Water in oil housing .............3

Overhaul  ..........................................3

- General .....................................3
- Mechanical seal inspection......3
- Lubrication ...............................4
- Inspecting the hydraulic parts  4
- Inspecting the motor cable ......4

Detailed Overhaul ............................4