12
control
function
The overload indicator light comes on
when an overload of a connected electrical
device is detected, the inverter control unit
overheats, or the AC output voltage rises.
Then, the AC protector will trip, stopping
power generation in order to protect the
generator and any connected electric
devices. The AC pilot light (Green) will go
off and the overload indicator light (Red) will
stay on, but the engine will not stop running.
When the overload indicator light comes on
and power generation stops, proceed as
follows:
1. Turn off any connected electric devices
and stop the engine.
2. Reduce the total wattage of connected
electric devices within the rated output.
3. Check for blockages in the cooling air
Inlet and around the control unit. If any
blockages are found remove.
4. After checking, restart the engine.
TIP:
The overload indicator light may
come on for a few seconds at first when
using electric devices that require a large
starting current, such as a compressor or a
submergible pump. However, this is not a
malfunction.
The AC pilot light comes on when the engine
starts and produces power.
OvERlOAD INDICATOR lIGHT (RED)
AC PIlOT lIGHT (GREEN)