background image

JAT-820 Pneumatic Flux Chipper 

 

20.  Do not use power tools in damp or wet 

location, or expose them to rain. Keep work 
area well lighted. 

21.  Do not leave a connected tool unattended. 

When not in use, disconnect tool from air 
source. 

22.  Shut off air supply and discharge any residual 

pressure from tool before removing hose, 
making adjustments, changing accessories, 
or storing tool. 

23.  Make sure tool is switched off, and your finger 

off the trigger, before connecting to air supply. 

24.  Remove adjusting keys and wrenches before 

turning on tool. 

25.  Keep visitors a safe distance from the work 

area. 

Keep children away.

 

26.  Give your work undivided attention. Looking 

around, carrying on a conversation and 
“horse-play” are careless acts that can result 
in serious injury. 

27.  Do not force a tool or attachment to do a job 

for which it was not designed. The right tool 
will do the job better and more safely. 

28. Repetitive motions and/or exposure to 

constant vibration can be harmful to hands 
and arms. Take frequent breaks and relax 
hands during extended operation. Change 
posture to avoid discomfort or fatigue. 

29.  Compressed air can be harmful if directed 

toward sensitive areas of the body, and may 
propel small particles caught in the air stream. 
Exercise proper caution. 

30. 

Use only recommended accessories; 
improper accessories may be hazardous. 

31.  Maintain tools with care. Keep air tool clean 

and oiled for best and safest performance. 

32. Do not use combustible gases, carbon 

dioxide, oxygen or any bottled gas as an air 
source for the tool. These can present risk of 
explosion and serious injury. 

33.  Do not lubricate the tool with combustible 

liquids, such as kerosene, diesel or jet fuel. 

34.  Do not dispose of this tool with normal 

household waste. Never dispose of the air tool 
into fire. 

Specific warnings for Flux Chipper 

35.  A flux chipper is used to remove rust, scale, 

paint and such like from metal surfaces. If you 
are not familiar with the proper and safe 
operation of a flux chipper, do not use until 
proper training and knowledge have been 
obtained. 

36.  Secure workpiece with clamps or vise; do not 

hold workpiece by hand. 

37.  Use only chisels that are designed for use with 

a flux chipper. 

38.  Use both hands to operate chipper. Keep 

hands away from chisel area. 

39.  Make sure chisel is secured within the tool. An 

unsecured chisel may be ejected from the tool 
during operation and cause possible injury. 

40.  Keep chisel tip against work surface. Do not 

use excessive force – let the tool do the work. 

41.  If chipper will not remove material from the 

work surface, discontinue use. Use alternate 
methods for removal. 

Familiarize yourself with the following safety notices used in this manual: 

 

This means that if precautions are not heeded, it may result in serious, or even 

fatal, injury.

 

  

This means that if precautions are not heeded, it may result in minor injury and/or 

possible tool damage.

 

 

 

Содержание JAT-820

Страница 1: ...Pneumatic Flux Chipper 505820 JAT 820 Operation Parts Manual M 505820 Edition 1 02 2015 JET 427 New Sanford Road LaVergne TN 37086 Ph 800 274 6848 www jettools com Copyright 2015 JET ...

Страница 2: ...n needed JET has Authorized Service Centers located throughout the United States For the name of an Authorized Service Center in your area call 1 800 274 6846 or use the Service Center Locator on the JET website More Information JET is constantly adding new products For complete up to date product information check with your local distributor or visit the JET website How State Law Applies This war...

Страница 3: ...hromium from chemically treated lumber Your risk of exposure varies depending on how often you do this type of work To reduce your exposure to these chemicals work in a well ventilated area and work with approved safety equipment such as face or dust masks that are specifically designed to filter out microscopic particles 9 Do not operate an air tool continually at full throttle without a work loa...

Страница 4: ...31 Maintain tools with care Keep air tool clean and oiled for best and safest performance 32 Do not use combustible gases carbon dioxide oxygen or any bottled gas as an air source for the tool These can present risk of explosion and serious injury 33 Do not lubricate the tool with combustible liquids such as kerosene diesel or jet fuel 34 Do not dispose of this tool with normal household waste Nev...

Страница 5: ...n this document The instructions and warnings in this manual may not encompass all possible workplace environments The operator is expected to take appropriate precautions and exercise common sense As with any tool operation safety of operator and bystanders should be first priority If there are questions or comments please contact your local supplier or JET JET can also be reached at our web site...

Страница 6: ...e lever Grip Inline Overall Length 13 1 8 in 333 38 mm Housing material Steel Net weight 3 81 lb 1 73 kg Shipping weight 4 14 lb 1 88 kg 1 The specified values are emission levels and are not necessarily to be seen as safe operating levels As workplace conditions vary this information is intended to allow the user to make a better estimation of the hazards and risks involved only Specifications we...

Страница 7: ... and rest chisel tip against work surface 7 Press throttle lever Pressure against throttle lever determines speed of tool Do not exert excessive pressure against work surface let the tool do the work 8 Release throttle lever to stop flux chipper 9 To remove chisel rotate knurled collar until hole aligns with ball Maintenance Lubrication The flux chipper should be lubricated daily or before each us...

Страница 8: ...r the job Continued use in either capacity will cause damage to the tool Tool Pressure JET Air Tools operate on 70 to 100 psi pounds per square inch air pressure measured at the tool when the tool is operating Set tool to 90 psi unless indicated otherwise Pressure in excess of 100 psi will shorten the life of the tool Air System Recommendations Equip the air compressor intake with a replaceable ai...

Страница 9: ...JET 9 Figure 2 Recommended arrangement of air piping and air line system ...

Страница 10: ...t lubrication Lubricate with air tool oil according to instructions in this manual Loss of power erratic action Low air pressure Verify compressor has proper CFM rating for tool Check compressor regulator setting set air pressure to 90 psi Check for loose connections Moisture or obstruction in air hose Air supply must be clean and dry Clean out air hose s and remove any kinks or bends Improper siz...

Страница 11: ...ttle lever 1 8 F25 08 Roll pin 3x20 1 9 F25 09 Main valve 1 11 F25 13 Upper main valve 1 12 F25 12 Lower main valve 1 Index Part No Description Qty 13 F25 11 Pin 2 8x11 2 14 F25 14 Piston 1 15 JAT820 15 Cylinder 1 16 F25 16 Piston sleeve 1 17 F25 17 Lock ring 1 18 SB 7 16 Steel ball 7 16in 1 19 F25 19 O Ring 23 7x3 5 4 20 F25 20 Knurled collar 1 21 F25 21 Snap ring S28 1 22 F25 22 Chisel 1 RBK 25 ...

Страница 12: ...epartment call 1 800 274 6848 Monday through Friday 8 00 a m to 5 00 p m CST Please have the stock number and serial number of your tool available when you call so that we may serve you quickly and accurately 427 New Sanford Road LaVergne Tennessee 37086 Phone 800 274 6848 www jettools com ...

Отзывы: