Electrical Connections
All electrical connections must
be done by a qualified electrician.
All adjustments or repairs must be done with the
dust collector disconnected from the power source,
unplugged. Failure to comply may result in serious
injury!
The DC-1200VX
single phase
dust collectors are rated
for
230V Only
. The dust collector is not supplied with a
plug. Use a plug and outlet rated at least 20 amps. The
circuit for the machine should also be protected by at
least a 20 amp circuit breaker or fuse.
The DC-1200VX
three phase
dust collectors are rated
for 230V/460V,
Prewired 230V.
If you wish to run these
on 460 volt, refer to the wiring diagram found on the
inside of the switch box cover.
Keep in mind that a circuit being used by other
machines, tools, lights, heaters, etc. at the same time
will add to the electrical load. A dedicated circuit to the
dust collector will give you the best results since dust
collectors are generally used at the same time other
tools are running.
Turning the Machine On & Off
This machine is intended for
indoor use only.
All Models
Before hooking up to the power source, make sure that
the switch is in the off position.
Turn the dust collector on by pressing the
Start
button
mounted next to the motor. Press the
Stop
button to turn
off the dust collector.
Remote Control
(Optional Accessory)
The DC-RC230 RF Remote Power Control unit is
available as an optional accessory (contact Customer
Service by calling the number on the cover).
Important:
The
DC-RC230
Remote Power Control
can
be used for activating Dust Collection units powered by
230V
only
up to 3HP,
single phase only
.
Figure 13A Figure 13B
Dust Collector RF Remote
Power Control
(optional)
The
DC-RC230
Remote Power Control
(Figure 14)
should be used for activating Dust Collection units
powered by 230V
only
up to 3HP, 1 Phase. The DC-
RC230 Remote Power Control
unit is rated at 230
V,
Single Phase
only. Use an outlet rated at least 20amps.
The circuit for the device being controlled by the DC-
RC230
should also be protected by at least a 20 amp
circuit breaker or fuse.
Before hooking up to the power source, make sure that
the switch is initially in the off position on both the dust
collector and
remote control unit
(Figure 13).
Turning the DC-RC230
On & Off
This machine is intended for
indoor use only.
1.
Plug the dust collector into the
main unit
(Figure 14) and plug the main unit into the power
outlet.
To start a machine or device:
1. Turn the machine itself on.
2. On the main unit place the switch to the
ON
position
(Figure 13A). The red LED on the main unit should
light up.
3. Press the button on the
remote control transmitter
(Figure 14) to turn the machine on.
4. To stop the machine, press the button on the
remote control transmitter
again.
Figure 14
When the machine is running, it can be stopped by
placing the switch on the main unit in the off position
(Figure 14). To restart, repeat steps 3 and 4.