background image

 14

 

Allow  all  excess  water  to  drain  off  the  filter. 
While the filter does not need to be absolutely 
dry, do not return to service if water is dripping 
or droplets are still visible. 

 

Low pressure compressed air may be used to 
remove any remaining water from the filter. 

 

Install the filters in reverse of the removal. The 
outer filter has directional air flow arrows printed 
on the frame which depicts the direction  of air 
flow. Make sure it is facing the proper direction 
when  installed.  If  no  directional  arrows  are 
present,  the  inboard  side  of  the  filter  will 
typically  have  metal  support  not  used  on  the 
outboard side. 

10.2.2  Dry Filters 

Dry filters are those filters which should not get wet. 
The standard Electrostatic Outer Filter (P/N 708731) 
is a dry filter. 

Cleaning may be completed by vacuuming using a 
brush attachment on the vacuum hose. 

 

Lightly brush the vacuum brush nozzle over the 
input  side  of  the  filter.  The  brush  will  help 
dislodge  the  particles  which  will  then  be 
removed by the vacuum. 

 

Make  several  passes  moving  inline  with  the 
pleats of the filter.  

 

Visually  inspect  the  filter  while  cleaning.  If  the 
filter material is worn, torn, or coming apart from 
the frame, it must be replaced. 

10.3  

RF Remote Control Replacement

 

 

Figure 10-3 

The  remote  control  provided  with  the  AFS  unit  is 
programmed and ready to operate once the unit is 
installed. Verify that the batteries are installed in the 
remote. 

Follow  these  instructions  if  the  remote  is  being 
replaced. 

1.  Place the Power switch in the ON position. 

2.  DO NOT press the ON/OFF button. 

3.  Press  and  hold  the  SPEED 

  (minus)  and 

SPEED + (plus) buttons on the control panel at 
the  same  time  and  hold  for  two  seconds.  The 
screen flashes (0.5 seconds) and displays "---" 
to enter the programming mode. 

4.  Press  and  hold  the  ON/OFF  button  of  the 

REMOTE  control  until  the  panel  is  turned  ON 
("ON"  is  displayed),  and  the  programming  is 
complete. 

5.  In  the  programming  mode,  press  any  other 

button  on  the  control  panel  to  exit  the 
programming mode. 

6.  In the programming mode, if the  programming 

is not completed within seven seconds, you will 
leave the programming mode. 

10.4  Cleaning Sensors 

Dust may accumulate on the sensor (see Fig. 8-3) 
and affect the performance in AUTO mode.  Sensor 
may be cleaned with a dry cloth or compressed air. 

10.5  Sensor Replacement 

The AFS unit ships from the factory with the sensor 
and  control  board  calibrated  and  ready  to  use.    In 
the event the sensor should need replacing, follow 
these instructions to calibrate the new sensor: 

1.  With the Power ON/OFF switch (Fig. 10-4, A) in 

the  OFF  position,  press  and  hold  the  Timer-
DN(-) and Timer-UP(+) buttons simultaneously, 
then  switch  the  Power  ON/OFF  switch  to  the 
ON  position  to  enter  the  environment  value 
setting mode. 

2. 

The  screen  flashes  and  displays  “

-  -",  the 

calibration  is  completed  when  the  detected 
value is stable (- - disappears), and then returns 
to the standby state. 

 

 

 

 

 

Figure 10-4 

10.6  Control Board Replacement 

In  the  event  the  control  board  needs  replacing, 
follow  the  steps  in  Section  10.5  to  calibrate  the 
sensor  with  the  new  control  board.    Then  follow 
these instructions to program the remote to operate 
with the new control board: 

1.  Recalibrate the sensor to the new control board. 

2.  Pair  the  new  control  board  with  the  remote  

control, reference Section 10.3. 

 

 A 

 B 

Содержание AFS-1000C

Страница 1: ... 427 New Sanford Road LaVergne Tennessee 37086 Part No M 713000 Ph 800 274 6848 Edition 3 12 2021 www jettools com Copyright 2021 JET Operating Instructions and Parts Manual AFS 1000C Air Filtration System ...

Страница 2: ...sed to accommodate a two prong receptacle the adapter lug must be attached to a known ground Never remove the third prong 15 WARNING Drilling sawing sanding or machining wood products generates wood dust and other substances known to the State of California to cause cancer Avoid inhaling dust generated from wood products or use a dust mask or other safeguards to avoid inhaling dust generated from ...

Страница 3: ...device may not cause interference 2 This device must accept any interference including interference that may cause undesired operation of the device This equipment complies with IC RSS 102 radiation exposure limits set forth for an uncontrolled environment L émetteur récepteur exempt de licence contenu dans le présent appareil est conforme aux CNR d Innovation Sciences et Développement économique ...

Страница 4: ...0 Operation 12 10 0 User maintenance 13 10 1 Changing the Filters 13 10 2 Cleaning the Filters 13 10 2 1 Washable Filters 13 10 2 2 Dry Filters 14 10 3 RF Remote Control Replacement 14 10 4 Cleaning Sensors 14 10 5 Sensor Replacement 14 10 6 Control Board Replacement 14 11 0 Troubleshooting 15 12 0 Replacement Parts 16 12 1 1 AFS Unit Exploded View 16 12 1 2 AFS Unit Parts List 17 12 2 1 Display M...

Страница 5: ...tended to be an exhaustive guide to air filtration systems Additional knowledge can be obtained from experienced users or trade articles Whatever accepted methods are used always make personal safety a priority If there are questions or comments please contact your local supplier or JET JET can also be reached at our web site www jettools com Retain this manual for future reference If the machine ...

Страница 6: ...CE o Fan Speed 6 levels o Timer setting 1 to 16 hours in 1 hour increments automatically shuts off when timer runs out High efficiency Brushless DC motor o Improved durability o Quieter operation o More energy efficient Auto Mode o In Auto Mode the unit monitors ambient air quality using an integrated PM2 5 sensor and adjusts fan speed to compensate o More air flow when it s needed to quickly impr...

Страница 7: ...125V Overload protector 5A Performance Fan Speed Air flow without filter CFM 1 Sound rating 1m 1 1 450 10 51dB 2 560 10 56dB 3 670 10 60dB 4 780 10 63dB 5 890 10 66dB 6 1000 10 67dB Control Panel On off switch Rocker switch Speed control Six selectable speeds Timer Setting Hour 1 16 LED display Display LED module Digital Remote Control Transmitter Radio Frequency Battery CR2032 3 Volt Button Cell ...

Страница 8: ...eight lbs 41 8lbs 19 kg 1 Variable of 10 for general information only not to be viewed as fixed parameters for inspection purposes L length W width H height n a not applicable The specifications in this manual were current at time of publication but because of our policy of continuous improvement JET reserves the right to change specifications at any time and without prior notice without incurring...

Страница 9: ... be capable of supporting the weight of the air filtration unit and absorbing any vibrations arising from the unit Appropriate fasteners must be used to secure to the ceiling Failure to comply may cause serious injury Never mount to surfaces such as dry wall false ceiling grids etc When overhead mounting such as a ceiling make sure chain and ceiling hooks are properly rated for hanging this unit R...

Страница 10: ...reen with or without yellow stripes is the equipment grounding conductor If repair or replacement of the electric cord or plug is necessary do not connect the equipment grounding conductor to a live terminal Check with a qualified electrician or service personnel if the grounding instructions are not completely understood or if in doubt as to whether the tool is properly grounded Failure to comply...

Страница 11: ...ing AFS unit goes to STANDBY state All DISPLAYS are off and the fan stops TIMER control panel or remote The TIMER buttons Fig 8 1 and 8 2 on the controls and the remote perform the exact same function under the exact same conditions The TIMER may be set in 1 hour increments from 1 to 16 hours When the timer expires the fan will stop and the AFS will enter STANDBY state When the timer is not being ...

Страница 12: ...e AUTO mode and return to manual mode NOTE In AUTO mode the unit may require several minutes to return to fan speed 1 once dust is detected The unit intentionally ramps down slowly to ensure good shop air quality FILTER STATUS INDICATOR control panel The FILTER status indicators are located on the control panel and are there to indicate the condition of the filters GOOD indicates that the filters ...

Страница 13: ... To reduce the risk of injury disconnect the air filtration system from the power source unplug before servicing or changing filters Failure to comply may cause serious injury This AFS is designed to remove airborne non metallic dust particles from the air Cleaning is about removing those particles from the filter in the opposite direction from which it came It is recommended to clean both filters...

Страница 14: ...he ON OFF button 3 Press and hold the SPEED minus and SPEED plus buttons on the control panel at the same time and hold for two seconds The screen flashes 0 5 seconds and displays to enter the programming mode 4 Press and hold the ON OFF button of the REMOTE control until the panel is turned ON ON is displayed and the programming is complete 5 In the programming mode press any other button on the ...

Страница 15: ...dentify sources of interference and eliminate them or relocate unit Remote control or machine control panel malfunction Contact JET customer service Unit not working efficiently not cleaning air Filter not installed properly Reinstall filter Blocked air flow Inspect filter replace if clogged remove blockage Controls on unit not working Control button or PCBA malfunction Contact JET customer servic...

Страница 16: ...s To order parts or reach our service department call 1 800 274 6848 Monday through Friday 8 00 a m to 5 00 p m CST Having the Model Number and Serial Number of your machine available when you call will allow us to serve you quickly and accurately 12 1 1 AFS Unit Exploded View ...

Страница 17: ...ssembly SEE 12 3 1 for detail 1 21 AFS1000C 021 Eye bolt M6X20 4 22 AFS1000C 022 Standoff M6X25 4 23 TS 1550041 Flat washer M6 13 24 TS 1534032 Screw Pan Head Phillips M6X10 5 25 TS 2286202 Screw Pan Head Phillips M6X20 2 26 AFS1000C 023 Hex head bolt M6X300 6 27 TS 1551041 Spring washer M6 7 28 AFS1000C 024 Screw Pan Head Phillips Tapping screw M5X12 8 29 AFS1000C 025 Flat head screw Tapping scre...

Страница 18: ...isplay Module Assembly 1 8 1 AFS1000C DM1 AC power switch 1 8 2 AFS1000C DM2 Display label 1 8 3 AFS1000C DM3 Auto button 1 8 4 AFS1000C DM4 Display cover 1 8 5 AFS1000C DM5 Display PCB 1 8 6 AFS1000C DM6 Screw Pan Head Phillips Tapping screw M3X6 6 8 7 AFS1000C DM7 Control module 1 8 8 AFS1000C DM8 Screw Pan Head Phillips Tapping screw M4X10 4 ...

Страница 19: ...escription Size Qty 20 AFS1000C RCA Remote Control Assembly 1 20 1 AFS1000C RC1 Remote label 1 20 2 AFS1000C RC2 Remote front case 1 20 3 AFS1000C RC3 Remote PCB 1 20 4 AFS1000C RC4 Button cell CR2032 1 20 5 AFS1000C RC5 Remote rear case 1 20 6 AFS1000C RC6 Battery cover 1 20 7 AFS1000C RC7 Remote FCC label 1 ...

Страница 20: ...20 13 0 Electrical Connections 115V Power Switch Display PCB CN1 CN2 CN2 Control Module Motor Thermal Fuse Power Cord Dust Sensor ...

Страница 21: ...itional action needed JET has Authorized Service Centers located throughout the United States For the name of an Authorized Service Center in your area call 1 800 274 6846 or use the Service Center Locator on the JET website More Information JET is constantly adding new products For complete up to date product information check with your local distributor or visit the JET website How State Law App...

Страница 22: ...22 NOTES ...

Страница 23: ...23 NOTES ...

Страница 24: ...24 427 New Sanford Road LaVergne Tennessee 37086 Phone 800 274 6848 www jettools com ...

Отзывы: