Solid State Heading Sensor (SSHS) Owner’s Manual
30
5. Continue turning the vessel through at least 3 circles until you see one of the following
manufacturer’s proprietary sentences:
• $IITXT,01,01,02,Deviation Calibration Successfully Completed*17<CR><LF>
This sentence indicates a successful calibration and you can jump to step
number 6.
• $IITXT,01,01,03,Deviation Calibration Failed To Complete*43<CR><LF> This
sentence indicates that the calibration failed (return to step number 1).
6. Turn the periodic transmissions back on by sending the following manufacturer’s
proprietary NMEA0183 sentence to the SSHS - $PMAREXE,SSHS,,FD,1,,,<CR><LF>
7. Proceed to Installation-Offset Correction.
SSHS NMEA 0183 Installation-Offset Correction
Installation-offset correction can be performed by sending a manufacturer’s proprietary NMEA
0183 sentence to the SSHS. The procedure is as follows:
1. Make sure the vessel is laying in flat water on a known heading.
2. Send the following manufacturer’s proprietary NMEA 0183 sentence to the SSHS:
$PMAREXE,SSHS,,24,”known heading in tenths of degrees”,,,<CR><LF>
Where “
known heading in tenths of degrees
” is expressed in 10
th
of degrees (i.e., 121.7°
would be programmed as 1217)
Sending this manufacturer’s proprietary NMEA 0183 sentence to the SSHS causes the
heading, roll, and pitch offsets to be written to permanent memory.
Содержание Nobeltec SSHS
Страница 1: ...www nobeltec com Nobeltec Owner s Manual Solid State Heading Sensor SSHS RAHSU00001 rev 03 07...
Страница 2: ......
Страница 4: ...Solid State Heading Sensor SSHS Owner s Manual ii...
Страница 6: ...Solid State Heading Sensor SSHS Owner s Manual ii...
Страница 28: ...Solid State Heading Sensor SSHS Owner s Manual 22...
Страница 47: ...APPENDIX B NMEA 2000 INTERFACING Jeppesen Marine 41...