8
3-Wire Cable from Home Power Supply - U.S.A. Only
IMPORTANT:
Use the 3-wire cable from power supply where
local codes permit connecting the frame-ground conductor to
the neutral (white) junction box wire:
1.
Disconnect power.
2.
Remove junction box cover, if present.
3.
Connect the 2 red wires (B) together using a UL listed wire
connector.
4.
Connect the green (or bare) ground wire (C) from cooktop
cable to the white (neutral) wire (F) in the junction box using a
UL listed wire connector.
5.
Connect the 2 black wire (H) together using a UL listed wire
connector.
6.
Reinstall junction box cover.
Complete Installation
1.
Check that all parts are now installed. If there is an extra
part, go back through the steps to see which step was
skipped.
2.
Check that you have all your tools.
3.
Dispose of/recycle all packaging materials.
4.
Use a mild solution of liquid household cleaner and warm
water to clean cooktop before use. Dry thoroughly with a soft
cloth. For more information, see the “Cooktop Care” section
of the Use and Care Guide.
5.
Read the “Cooktop Use” section in the cooktop Use and
Care Guide.
6.
Reconnect power.
7.
Test the operation of the cooktop: verify that it heats and
the control light illuminates in the Hi, Med, and Lo positions.
Press OFF when done.
NOTE:
If the cooktop does not work after turning on the power,
check that a circuit breaker has not tripped or a household fuse
has not blown. See the “Troubleshooting” section in the Use and
Care Guide for further information.
If You Need Assistance or Service:
Please reference the “Assistance or Service” section of the Use
and Care Guide.
B
C
D
A
E
F
H
G
I
A. 3-wire cable from power supply
B. Red wires
C. Green (or bare) ground wire
from cooktop
D. 3-wire cable (from cooktop)
E. Junction box
F. White wire (from home power
supply)
G. UL listed wire connector
H. Black wires
I. UL listed or CSA approved
conduit connector with wire
bushing