Testing Procedures
!
WARNING
To avoid risk of electrical shock, personal injury or death; disconnect power range before servicing, unless testing
requires power.
20 16026926
© 2006 Maytag Services
Switch Membrane Assembly
Test Procedure
Results
JES9800BA*,
JES9900BA*
Closed circuitry resistance
(defined as continuity): 2000 Max
Ω
Pins 1 & 10 are shorted together for control
configuration purposes
Detail B
See Detail B
Trace # 1
Latch
Pad
1
2
3
4
5
6
7
8
9
0
Cancel
Bake
Broil
Clean
Convect
Favorites
Rapid Preheat
Vent Fan
More Options
Setup
ATM 1
ATM 2
Back
Enter
Timer 1
Timer 2
Oven Light
Trace
2 & 7
2 & 8
2 & 9
2 & 10
2 & 11
2 & 12
3 & 6
3 & 7
3 & 8
2 & 6
4 & 9
4 & 10
4 & 11
5 & 7
5 & 9
4 & 12
5 & 10
5 & 11
5 & 8
5 & 6
4 & 6
4 & 7
3 & 9
3 & 10
3 & 11
3 & 12
4 & 8
Measurement
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Electronic Oven Control (EOC) III Testing Procedures
Warm
Drawer
ATM PADS
ELECTRONIC OVEN CONTROL III TESTING/PROGRAMMING PROCEDURES
Feature
Access Procedure
Modification Procedure
Control Reset
Resets control to factory default
values.
Press the
Setup
pad, then press the right
ATM
pad until SERVICE displays. Press the left
ATM
pad to select SERVICE menu options.
Press and hold the
Back
and
Enter
pads
for 5 seconds to enter SERVICE menu
options. Press the right
ATM
pad to scroll
to CONTROL RESET. Press the left
ATM
pad to select CONTROL RESET, then
press the left
ATM
pad again to reset the
control logic. Press
Setup
to exit.
Oven Temperature Adjustment
Determines oven cavity offset
temperature (range from -35° F to
+35° F, or -21° C to +21° C).
Press the
Setup
pad, then press the right
ATM
pad until TEMP ADJUST displays. Press the
left
ATM
pad to select oven TEMP
ADJUSTMENT settings.
Enter the offset temperature setting desired
using the digits pads. Press the right
ATM
pad for + temperature adjustment, or the
left
ATM
pad for – temperature adjustment.
Press 0 to reset control back to no
temperature adjustment. Wait 3 seconds
for the control to accept the request. Press
Setup
to exit.
Содержание JES8750BA Series
Страница 50: ...B 2 16026926 2006 Maytag Services Use Care Information ...
Страница 51: ... 2006 Maytag Services 16026926 B 3 Use Care Information ...
Страница 52: ...B 4 16026926 2006 Maytag Services Use Care Information ...
Страница 53: ... 2006 Maytag Services 16026926 B 5 Use Care Information ...
Страница 54: ...B 6 16026926 2006 Maytag Services Use Care Information ...
Страница 55: ... 2006 Maytag Services 16026926 B 7 Use Care Information ...
Страница 56: ...B 8 16026926 2006 Maytag Services Use Care Information ...
Страница 57: ... 2006 Maytag Services 16026926 B 9 Use Care Information ...
Страница 58: ...B 10 16026926 2006 Maytag Services Use Care Information ...
Страница 59: ... 2006 Maytag Services 16026926 B 11 Use Care Information ...
Страница 60: ...B 12 16026926 2006 Maytag Services Use Care Information ...
Страница 61: ... 2006 Maytag Services 16026926 B 13 Use Care Information ...
Страница 62: ...B 14 16026926 2006 Maytag Services Use Care Information ...
Страница 63: ... 2006 Maytag Services 16026926 B 15 Use Care Information ...
Страница 64: ...B 16 16026926 2006 Maytag Services Use Care Information ...
Страница 65: ... 2006 Maytag Services 16026926 B 17 Use Care Information ...
Страница 66: ...B 18 16026926 2006 Maytag Services Use Care Information ...
Страница 67: ... 2006 Maytag Services 16026926 B 19 Use Care Information ...