PRODUCT MODEL NUMBERS

CVEX4100

CVEX4270

CVEX4370

PRODUCT DIMENSIONS

ELECTRICAL REQUIREMENTS:

Before You Make the Electrical Connection:

● 

A 4-wire or 3-wire, single phase, 120/240 volt, 60 Hz., AC only electrical supply is
required on a separate, 40-amp circuit (30" [76.2 cm] models), 20-amp circuit 
(20" [50.8 cm] models) or 60-amp circuit (45" [114.3 cm] models), fused on both
sides of the line.

A. Side clearance - See *NOTE.
B. 4¾" (12.0 cm)

C. 6¼" (15.9 cm)
D. Grease container

E. 2" (5.0 cm) min. to cabinet, 

6" (15.2 cm) recommended to motor service

F. 12½" (31.8 cm)

G. 17½" (44.5 cm)

B

C*

G

A

D

E**

F

20" (50.8 cm) Single Cartridge Cooktop

A. 19¼" (48.9 cm)
B. 21

¹⁄₈

" (53.6 cm)

C. Grease container
D. Blower

A

B

C

D

*

NOTE: 

Grills installed near a side wall must allow a minimum clearance of 6"

(15.2 cm) between cooktop and sidewall for maximum performance. Minimum
clearance of 1" (2.5 cm) is required to sidewalls and 

³⁄₄

" (1.9 cm) to rear wall.

*

*A minimum clearance of 6

¹⁄₄

" (15.9 cm) is recommended for removal of the

grease filter(s). Installed dimension for the grease filter(s) is 5

¹⁄₂

" (14.0 cm).

**A minimum clearance of 2" (5.1 cm) is required between the blower motor and

cabinet for proper cooling. A clearance of 6" (15.2 cm) is recommended to allow
for blower motor service.

B

C*

E**

F

A

H

D

D

G

30" (76.2 cm) Double Cartridge Cooktop

A. 30

¹⁵⁄₁₆

" (78.6 cm)

B. 21

¹⁄₈

" (53.6 cm)

C. Grease container
D. Blower

A. Side clearance - See *NOTE.
B. 4¾" (12.0 cm)

C. 6¼" (15.9 cm)
D. Grease containers

E. 2" (5.0 cm) min. to cabinet, 

6" (15.2 cm) recommended to motor service

F. 12½" (31.8 cm)

G. 11

⁷⁄₁₆

" (29.1 cm)

H. 17½" (44.5 cm)

A

B

C

D

*

NOTE: 

Grills installed near a side wall must allow a minimum clearance of 6" 

(15.2 cm) between cooktop and sidewall for maximum performance. Minimum
clearance of 1" (2.5 cm) is required to sidewalls and 

³⁄₄

" (1.9 cm) to rear wall.

*

*A minimum clearance of 6

¹⁄₄

" (15.9 cm) is recommended for removal of the grease

filter(s). Installed dimension for the grease filter(s) is 5

¹⁄₂

" (14.0 cm).

**A minimum clearance of 2" (5.1 cm) is required between the blower motor and cabinet

for proper cooling. A clearance of 6" (15.2 cm) is recommended to allow for blower
motor service.