20 Basic
service
Basic service
Before servicing the Roadie Compact, read and observe all the precautions listed
in “Safety information” on page 3. Any service not described in this section must
be carried out by a Jem service technician.
C l e a n i n g
Excessive dust, smoke fluid, and dirt buildup will degrade performance and
cause overheating and damage to the machine that is not covered by the
product warranty. To maintain adequate cooling, dust must be cleaned from the
outer casing and air vents of the machine periodically.
Isolate the machine from power and allow to cool completely before cleaning.
The smoke output nozzle remains hot for up to 10 hours after use.
•
Remove dust from the air vents with a soft brush, cotton swab, vacuum,
or compressed air.
•
Clean smoke fluid residues from the fog output of the machine.
•
Clean the outer casing with a damp cloth only.
F u s e r e p l a c e m e n t
The main fuse for the Roadie Compact is in a fuse holder located adjacent to the
power inlet. To replace the fuse, disconnect the power cord from the supply,
unscrew the cap of the fuse holder and pull out the fuse. Remove the spent fuse
and replace with one of exactly the same size and rating. The fuse type is
indicated on the serial number label. Contact Jem Service if the fuse blows
repeatedly.
If the machine partially runs but some features do not operate, one of the
internal fuses may have blown. These fuses are located on the power pcb which
may be accessed by removing the power inlet panel.
DANGER! Isolate the machine from power before removing any panels. Live
electrical parts inside.
One output not operating: Check heater fuses FS1/FS2
Heating but not pumping / fan not working: Check FS3
Mains in OK but electronics power LED not lit: Check FS4.
Contact Jem Service if the problem persists.