Страница 1: ...s underutilized and idle equipment along with credit for buybacks and trade ins Custom engineering so your equipment works exactly as you specify Critical and expedited services Leasing Rentals Demos In stock Ready to ship TAR certified secure asset solutions Expert team I Trust guarantee I 100 satisfaction All trademarks brand names and brands appearing herein are the property of their respective...
Страница 2: ...bjects to maintain the product s functions and to use it safely Especially be sure to read Safety Precaution carefully before you use this equipment Please keep this instruction close to the equipment to use it after reading through it once Please place it where the new user can find it easily for the safety use when you hand over or lend the equipment to others ...
Страница 3: ...nsufficient points error and omission on the operating instruction Warning mark of the product 1 This operating instruction uses the warning Signal Word for safe operation to prevent the users from accidents or damage beforehand 2 It defines warning marks according to the level of importance and danger in order to use the product safely and correctly 3 Warning means that the user may have serious ...
Страница 4: ...It becomes the cause of electric shocks fires and improper operations 5 Please contact the agent or us in case of the component and the consumable parts of the product will be replaced 6 Do not give a strong shock to the product It becomes the cause of product damage and wrong operations Disclaimer 1 In no event will Jeio Tech industries be liable for any incidental or consequential damages for br...
Страница 5: ...amaged contact the delivery service company immediately 2 Keep the condition as it delivered and wait for the confirmation by the carrier 3 Within 15 days submit an application be made in writing to the delivery service company 3 Compensation regulation of transport 1 Any damage that is occurred during the transport is responsible to the delivery service company 2 Except for all damage from the tr...
Страница 6: ...unpacking the unit check the following components In addition check the features and electric condition Components EA Components EA unit 1 Power Cord 1 Operating instruction 1 Fuse 2 Software CD for communication 1 Spacer 4 Cable for communication 1 ...
Страница 7: ...sition of SI 300R 600R 11 5 Introduction 13 6 Controller instruction 16 7 How to change the orbital motion and reciprocation motion 38 8 Accessories 39 9 Cause of malfunction and its repairs 46 10 Inspection cycle 49 11 Maintenance and cleaning 50 12 Specification 51 13 Warranty standard 52 14 How to waste 53 15 Warranty 54 16 Setting monitoring program 55 17 Operating monitoring program 56 ...
Страница 8: ...ndent line 100V 120V 230V single phase a grounded and polarized 100V 120V 16AWG 12A 1 25SQ 230V 18AWG 10A 0 75SQ 5 Do not install the product in the place that the gas could leak out 6 Do not use in the place that has the industrial oil smoke and the metallic dust It causes fire or electric shock 7 Unplug when there is strange sound smell and smoke from the product Please request the service It ca...
Страница 9: ...the product in a dangerous article area 12 Never put inflammables and explosives in the product A sample may explode in the chamber at a high temperature The explosives are acetic acid ester nitro compounds etc and the inflammables are peroxides inorganic peroxides acetate and organic solvent This product was not designed to prevent from any explosion ...
Страница 10: ...ic shock or fire 6 Do not clean it with a strong cleanser like solvent type and use a soft cloth It may cause fire or modification of the product Clean it with a soft cloth dipping in neutral detergent Warnings and confirmations when operating the product 1 Insure a enough space because the cover is opened up to 70 2 Do not pull down the product and give a shock Operate it on a flat place 3 Please...
Страница 11: ...hed in the same place below until disusing the product If the safety alerts are damaged please request new labels to an agent or us Caution It shows the caution when opening and shutting the inner class door and the out door Warning It is to forbid putting inflammables and explosives inside of the product Caution If the air filter is being stopped up refrigeration efficiency would be decreased and...
Страница 12: ...omponents is isolated by a magnetic switch leaving only the earth in circuit Details of the fault are displayed indicator codes Audio and visual alarms are set off to alert the user and remain on until attended Shaking System Stop the one regular position The automatic system with Brake function allows the shakers can always stop at the same position Turn Right and Left both ways Our original Auto...
Страница 13: ...the open cover we are using a translucent acrylic cover and setting a lamp up Programmed auto run function Our integrated controller allows controlling the inner circulating fan speed on three steps The 9 Step Programmed Control system can make to auto run on nine different temperatures and times Max 99hr 59min and maximum 200 times for each time Safety device Independent IC logic detects and inte...
Страница 14: ...er temp LED illuminates with audible Beep sound When the power is shut down Please set the Knob over 15 than the setting value Press the Start Stop switch and then Check the Temp LED illumination 3 Communication Port The serial interface RS 232 can connect the PC through COM1 or COM2 port It s allow to check the condition of the unit and the setting value This interface can restore the data and th...
Страница 15: ...s the Microprocessor CPU can be performed Digital PID Auto tuning 12 Chamber Air Out Inner air is out to go through the heater or Evaporator 13 Temperature Sensor With Thin Film PT 100Ω 14 Blower Inner Blower for the temperature uniformity 15 Gas Spring Gas spring is for changing the sample conveniently 16 Door Switch There is door limit switch between door and the appliances mainframe upper parts...
Страница 16: ... is for protecting the unit from the momentary overpower When exchanging the Fuse check the main power Model Electric requirements Fuse Quantity Remarks 100V 50 60Hz 2 EA 120V 60Hz AC 250V 10A Slow blow 2 EA SI 300 600 230V 50Hz AC 250V 5A Slow blow 2 EA 100V 50 60Hz 2 EA 120V 60Hz AC 250V 12A Slow blow 2 EA SI 300R 600R 230V 50Hz AC 250V 8A Slow blow 2 EA 20 Drain Hose Nipple Drain hose nipple is...
Страница 17: ...he operator can use the Temp shaking function simultaneously Know well the operator to perform functions like temp shaking programmed all on the controller in right process 1 PV Display Indicates the present value 2 SV Display Indicates the set value or remaining time of the timer 3 rpm Display Indicates the actual rpm or rotation direction 1 2 3 4 5 7 8 9 6 ...
Страница 18: ...tes when pressing the START STOP Button Heater LED Indicates the heater output Auto tune LED Flahses during Auto tune function Wait on timer LED After setting time indicates starting point of the unit Illuminates while operating Wait off timer LED After setting time indicates the unit stops Flashing the timer LED during operation The timer LED is lit the timer is standing by Door LED When opening ...
Страница 19: ...Button Auto tune Function operates while pressing the button for a second SHAKE SET Button For Checkng the setting and present rpm and entering the new rpm value START STOP Button Starts and Stops the unit When the unit stops operating user can remove the beep sound and flashing LED with Start Stop Button 7 Lamp Button Turns On Off the inner Lamp 8 Shaker I O Button Shaker I O Buton Starts Stops t...
Страница 20: ...alue Starts the operation Control of the Temperature This control is for the chamber of the inner temp Controlling the temp other function and programming temp using of the Temp button Method of the setting temp Turns on the power switch and wait for the unit stabilized Press Temp button Flashing the number activated on the SV display Set the desired temp with Up button and Down button Press Enter...
Страница 21: ...ter button to finish setting Select the temp can be restored in CPU The PV temp will be changed Press Temp button once SV2 is displayed on the PV display Set the desired temp same as No 1 Press Temp button one The example of the set temp 1 The method of the set temp in SV1 to operate In case of the main screen Press TEMP button twice Dispalayed SV1 on the PV display and Set temp on the SV display ...
Страница 22: ...In case of the main screen Press the TEMP button twice Press Enter button once to display SV3 On the PV display After checking the SV 2 temp Press Enter button Press START STOP button to reoperate the controller The temp unit changing function This function is for changing the temp unit In case of the main screen press five times continuousluy The display changed Based with the Celcius setted Use ...
Страница 23: ... Bias on the SV display Use UP button and Down button to move the BIAS value display Displayed the PV on the SV display Set the temp measured by the thermometer Press Enter button to complete the BIAS function The value can be checked on the BIAS display Press Enter button once the unit starts controlling the temp by set value Use the thermometer approved When the temp revision is not done Contact...
Страница 24: ...in screen Press Timer button twice Off Timer can be set Press Up button and Down button to set the desired time Press button to finish Illuminates W ON LED with Beep sound after setting Cancellation of Wait On Off Timer Press timer button once displayed Wait on Timer Press timer button twice displayed Wiat Off Timer Wait on Cancellation Press Up button and Down button to make the value 0 zero Pres...
Страница 25: ...arts operation automatically after power is on Use Up button Dwon button Select YES or NO When setting YES the unit starts operation after power is on Fan speed controller function Press TIMER Button four times displayed Fan speed function This function is for controlling the inner fan speed When the fan speed is slow the temperature uniformity is not sutible Recommend uisng the NO 3 ...
Страница 26: ...erating the program Input No 0 Press Up button and Down button to select the desired value Press Enter button to finish the menu SEg L is for deviding the segment If input 3 NO 3 Prgram will repeate from the second segment Press Up button and Dwon button to select the desired value Press Enter button to finish the set Prg 1 is for inputing the maintenance time for the first stpe Press Up button an...
Страница 27: ...and Temp 3 be set This program function can be set till Prg 9 If input the time 00 00 in Prg3 the program is finished The program will be operated until Prg2 and step 2 Example of Prgrammed Control Input in Timer Button The maximum step is 9 If input the time 00 00 the step has been input until step 7 If the Loop is 10 and Seg L is 3 The step operates total 52cycles Total Step Step 1 Step 7 1 Cycl...
Страница 28: ...uminating A T LED Press START STOP butoon illuminating Run LED Auto Tunie will operate with flashing A T LED Auto tune time will be different depends on the circumtance After finishing the Auto tune The temp will be controled by Auto tune value While operating the unit Pres A T button for a second Auto Tune will be displayed Auto Tuning must operate in the first step Please operate the Auto tuning...
Страница 29: ... or rotate without the timer mode Press SHAKE SET button RPM displayed on the PV the previous rpm value displayed on the SV Use Up button and Down button to select the desired rpm Press Enter button to finish the mode Press START STOP button or Shake I O button to operate a shaker in stop position Or Press Enter button to start a shaker in working position If not selecting the rpm for 10seconds Th...
Страница 30: ...nd Down button Press Enter button to finish the mode Maximum Input time 1 999 hours Whole time MM SS set Set the minute and seconds Press SHAKE SET button three times run S will be appeared on PV display The previous time will be displayed on the SV Use Up button and Down button To set the time then Press Entr button The shake LED illuminates Maximum Input time 10seconds 59minutes 59seconds The wh...
Страница 31: ...KE SET button five times bAc S will be appeared on PV display The previous time will be displayed on the SV Use Up button and Dwon button To set the time then Press Button TheB WARD LED illuminates Maximum Input time 10seconds 59minutes 59seconds Pause time MM SS SET Press SHAKE SET button six times pAu S will be appeared on PV display The previous time will be displayed on the SV Use Up button an...
Страница 32: ... press the START STOP button or The Shaker I O button The whole time set Forward or Backward Action SHAKE LED illumination Forward LED or Backward LED illumination Select the hour or minutes in the whole time set Press Enter button to iluminate Shake LED After setting the forward or backward Press Enter button to iluuminate F WARD LED or B WARD LED The shaker starts operating until setting time Ru...
Страница 33: ... WARD LED 3 After setting the backward time Press Enter button to iluuminate F WARD LED or B WARD LED 4 Press the START STOP button the shkae operates the forward direction When the speed is a little slow the shaker operates following the set time in backward direction 5 The shaker operates the forward and backward direction following the whole time function When setting the F WARD or B WARD in 3m...
Страница 34: ...rward time orB WARD Press Enter button to iluuminate F WARD LED or B WARD LED 3 After setting the pause time Press Enter button to iluuminate PAUSE LED 4 Press the START STOP button the shaker operates the forward or backward direction When the speed is getting slow the shaker pause 5 After the pause time the shaker operates the forward and backward direction during set time 6 The forward and back...
Страница 35: ... until the set time The caution of the Timer Function When using the Timer fuction set each set value then must press Enter button to illuminate Display LED Even if illuminate SHAKE LED the shaker doesn t operate When not illuminating the FORWARD LED or BACKWARD LED The shaker doesn t operate even if illuminating SHAKE LED and PAUSE LED If not setting the time the shaker operates the shaker repeat...
Страница 36: ...ement display Function This Function is for displaying the presnt shaking table When maintaing rpm the display starts a circular movement Forward accelation Forward deceleration Backward accelation Backward deceleration ...
Страница 37: ...utton with YES on the SV display the Shaker Incubator operates at the same time Set No on the SV display The shaker doesn t operate Even if setting YES on the SV display the Shaker function can be On OFF with Shaker I O Switch Even if setting No on the SV display the Shaker function can be On OFF with Shaker I O Switch Shaker I O Switch This Switch is for controlling the Shaker On Off without the ...
Страница 38: ...m with Shake Set button Reference Page 22 Press SHAKE SET button the shaking table and incubator operates together Temp Controller Incubator only Select No on SV display Press Temp button to set the desired Temp Press START STOP button the incubator operates only Incubator Temp Controler START STOP Button Shaker Movement Controller START STOP or Shaker I O Switch ...
Страница 39: ...xed on the Vibration Frame Connect the Spacer referred Page 6 to the Vibrating Frame for linear motion Position the Shaking Table on the Spacer tight 4 pieces of 5mm Wrench Bolt The basic usage is the same as the orbital motion When changing the Orbital motion or Reciprocating motion Must change the Spacer The operator can use the Orbital motion or Reciprocating motion whatever wants 2 1 Orbital m...
Страница 40: ...aries 1 Flask Clamp installed Capacities and Drawings Model SI 300 300R 50 Flask Flask Clamp Location of fixed holes Maximum fixed numbers 28 EA 100 Flask Flask Clamp Location of fixed holes Maximum fixed numbers 24 EA ...
Страница 41: ...Page 40 Model SI 300 300R 250 Flask Flask Clamp Location of fixed holes Maximum fixed numbers 13 EA 500 Flask Flask Clamp Location of fixed holes Maximum fixed numbers 9 EA ...
Страница 42: ...Page 41 Model SI 300 300R 1 000 Flask Flask Clamp Location of fixed holes Maximum fixed numbers 4 EA 2 000 Flask Flask Clamp Location of fixed holes Maximum fixed numbers 2 EA ...
Страница 43: ...Page 42 Model SI 600 600R 50 Flask Flask Clamp Location of fixed holes Maximum fixed numbers 45 EA 100 Flask Flask Clamp Location of fixed holes Maximum fixed numbers 36 EA ...
Страница 44: ...Page 43 Model SI 600 600R 250 Flask Flask Clamp Location of fixed holes Maximum fixed numbers 18 EA 500 Flask Flask Clamp Location of fixed holes Maximum fixed numbers 13 EA ...
Страница 45: ...Page 44 Model SI 600 600R 1 000 Flask Flask Clamp Location of fixed holes Maximum fixed numbers 7 EA 2 000 Flask Flask Clamp Location of fixed holes Maximum fixed numbers 5 EA ...
Страница 46: ...0 4 EA 2000 1 EA SI 600 600R Flask Max Capacities EA Flask Max Capacities EA 50 25 EA 500 5 EA 100 16 EA 1000 4 EA 250 9 EA 2000 2 EA 3 Test tube rack Setting angle Model 0 60 Platform size SI 300R 2 EA 1 EA 330 X 330 mm SI 600R 4 EA 2 EA 410 X 410 mm Rack size 262 X 100 X 185 mm 0 262 X 163 X 208 mm 60 4 Separate funnel clamp 250 500 1000 5 Rubber mat Use for the flat vessels like Petri dish ...
Страница 47: ... Check the W ON LED is illuminated Release the Timer mode Check the dust on the Condenser Clean the filter opened the Condenser cover The temperature doesn t decrease Check the inner circulation fan speed is too low Adjust the fan speed high The temp is unstable Check the PID value Operates the Auto Tuning Reference page 27 Check the Blower speed Adjust the Blower fan speed high Reference page 24 ...
Страница 48: ...top button after currently adjusting than temperature PV higher than 15 red of O T Led disappears and a Beep sound disappears 2 While Run LED and Heater LED are on if they press one time of Start Stop button more a machine operates again If the unit stops operation by Door Limit Switch 1 Door Led is turned on with red 2 Confirms whether a Beep sound rings 1 Check whether Door LED is flickering due...
Страница 49: ... stops operation by START STOP Check Sync Parameter is no Reference Page 36 37 Select Sync Parameter is yes or Press Shaker I O Switch to operate When the shaker speed is up or down the display has any symptoms Check the unit location and Power Provide the main volt ...
Страница 50: ... Condition Shaker Noise Air Filter Cleaning Vibration Be sure to maintain the unit frequently by a person authorized Make no attempt to service or repair the unit when the power is on Be danger of Do not dismantle the unit If dismantling the unit may cause the personal injury or damage to the unit ...
Страница 51: ... 1 Wipe the exterior surface with a clean sponge or a soft fabric using a detergent 2 Rinse off with a dry fabric using a tepid water 3 Clean the controller Panel with a dry fabric Do not use sulfuric acid hydrochloric acid and organic solvent Solvent will damage the unit If the interior unit become contaminated by a toxic chemical wash the areas completely using a dry fabric with wearing safety g...
Страница 52: ...c Pause Forward Backward Max 59min 59sec Min 10sec Shaking Driving System Brushless DC motor with feedback control Internal Stainless Steel 1 0t External Steel 3 2t 2 0t powder coating Platform Anodized aluminum plate 4 0t Insulation Nonflammable polystyrene Lid With semitransparent acryl cover and supported by gas spring Heater Incoloy Fin Type 400W X 2EA Material Refrigerator 1 8 HBP 1 8 HBP Saf...
Страница 53: ...by warranty in case of as below If the machine is broken due to the Act s of God If the machine is broken due to overuse of voltage If there is some shock to the machine If the outer part is damaged by solvent If the machine is broken without taking care of the Notice alerted on the manual If persons who are not under the authority of service of Jeiotech fixed or changed parts of the machine If th...
Страница 54: ...arts Model Gross Weight kg External dimension mm WⅹDⅹH How to waste Main body SI 300 74kg 420ⅹ740ⅹ622 Main body SI 300R 85kg 420ⅹ740ⅹ622 Main body SI 600 91kg 540ⅹ842ⅹ622 Main body SI 600R 102kg 540ⅹ842ⅹ622 Contact a company which is dealing with waste parts 14 ...
Страница 55: ...he term of guarantee if as follows Purchase date Serial number A trouble part and trouble state Equipments use environment A use mistake of a user A mistake of treatment of a user and custody Unfair change of usage remodeling of a machine and acceptance It is trouble by acts of God such as a fire a brilliant trouble by the use that it did not keep operation manual ...
Страница 56: ...ation Default folder recommended 3 Click Install to start installation 4 Lab Tracer icon will be created on the desktop after successful installation 5 To start Lab Tracer double click the icon Standard Recommend Beyond Microsoft Windows 98 Microsoft Windows 2000 XP CPU Beyond P II 233 PU Beyond P III 300 RAM Beyond 32M Byte RAM Beyond 64M Byte Caution If Windows 95 or 98 OS system is installed me...
Страница 57: ...w consists of 2 separate windows Window on the top displays set temperatures and actual temperatures and window on the bottom displays output value of heating in a graph mode 2 View menu 2 1 If you click View Parameter window displays actual temperatures set temperatures and output of heating by a graph and figures 2 2 If you click View Status additional separated window appears below the window s...
Страница 58: ...sing Status and Parameter in View menu User can monitor operating process through three divided windows Graph Parameter Status 2 2 1 Graph displays Actual temperatures Red line and set temperatures Blue line on the top of the graph windows 2 2 2 Status displays ...
Страница 59: ... or not 2 2 3 Parameter displays 1 PV is an actual present temperature 2 SV is a set temperature 3 Heat is an output value of heating element 4 Run Time indicates operating time after you press button 5 Wait On Timer Wait Off Timer displays remaining time from a set time 6 Power Frequency displays frequency of a current power 3 Menu icon 1 2 3 4 5 6 7 8 9 10 11 12 13 1 File Open Ctrl O To open sav...
Страница 60: ...ppearance of displayed panel of unit pops up and you can control the unit by the pop up window 17 Set Pattern of Program Run Set Pattern of Program Run and makes unit in a programmable operation Maximum number of pattern is 100 during 99 hours 18 Program Run Program Run must be set in the main unit Program function can be controlled only by PC 19 22 Zoom In Out 23 24 Icons to convert the unit of t...
Страница 61: ...If not they will not be printed Current page Print a page on the current main screen Selected pages Print selected page s Number of copies Maximum number of copies is 100 by pressing up and down button PV print interval If you choose this option PV and SV will be printed in text mode Memo Can write a brief memo on print with maximum 60 characters Select Print Can choose a printer ...
Страница 62: ... regular interval like the preview above If user wants to check a certain point move curser to the point and click Green line with PV and SV will be printed on the copies see above Last Point Delete Delete the last set point All Point Delete Delete all set points Zoom in out Zoom in or Zoom out ...
Страница 63: ... on the left side of window Display All the functions of display window are same as those of main display panel If communication via RS 232 between PC and main body is connected user can control main body with your PC at a distance Pattern Program The following window will be open when you click PRG icon or Pattern Pattern settings in menu ...
Страница 64: ...degree and time can be adjusted by one minute Short key Increase temperature by 1 degree Decrease temperature by 1 degree Decrease time by 1 minute Increase time by 1 minute Alt Move an edited point to the right the following step Alt Move an edited point to the left a previous step Alt Move an edited point to the left a previous step Alt Move an edited point to the right the following step Last s...
Страница 65: ...rate ii The main body must be set as a Con P mode To convert to Con P mode press and hold the lock button for more than 1 second If you want to operate the unit in Con L mode Local mode press and hold lock button for more than 1 second Only lock button works in the display panel of main body at a Con P mode Pic 4 Step information and control option If you set the number of pattern repetition the m...
Страница 66: ... over 99 hours the unit does not operate in a Program Mode Especially be cautious when you program a pattern repetition Please be aware of specification about program time and temperature If you program the pattern that exceeds equipment capacity the unit can not work properly ...
Страница 67: ...Page 66 ...
Страница 68: ...Page 67 ...
Страница 69: ...quipment Have surplus equipment taking up shelf space We ll give it a new home Learn more Visit us at artisantg com for more info on price quotes drivers technical specifications manuals and documentation Artisan Scientific Corporation dba Artisan Technology Group is not an affiliate representative or authorized distributor for any manufacturer listed herein We re here to make your life easier How...