Operating Manual
Shaking Incubator
Model : ISF-7100, ISF-7200, ISF-7100R, ISF-7200R
Menual no. : XXXXXXXXXXX
Страница 1: ...Operating Manual Shaking Incubator Model ISF 7100 ISF 7200 ISF 7100R ISF 7200R Menual no XXXXXXXXXXX ...
Страница 2: ...ional Guidelines contained in this Manual and take all necessary safety precautions while using this product Failure to follow these guidelines could result in potentially irreparable bodily harm and or property damage Thank you for purchasing Jeio Tech s products We are doing best for customer s satisfaction ...
Страница 3: ...com to view a copy of our certificate Disclaimer Jeio Tech Co Ltd is committed to a continuing program of product development and improvement and reserves the right to change information such as specifications appearance and dimensions described in this document without notice Copyright No part of this manual may be reproduced or transmitted in any form or by any means including photocopying recor...
Страница 4: ... 11 3 2 Component 11 3 3 Preparation before installation 12 3 3 1 Space requirements 12 3 3 2 Environmental Setting 13 3 4 Installation 14 3 4 1 Caution for Installation 14 3 4 2 Adjusting the Horizontality 15 3 5 Attaching Condensate Drain 16 3 6 Attaching Detaching External Refrigeration ISF 7100 ISF 7200 Only 16 3 7 Connecting Power 18 4 Operation 19 4 1 Controller 19 4 2 How to use the control...
Страница 5: ...lacement 36 6 Troubleshooting 38 6 1 Stop during the operating 38 6 2 Another problem and solution 39 7 Accessories 41 7 1 Mountable maximum quantity 41 7 1 1 Universal Platform Flask Clamp 41 7 1 2 Universal Platform Plastic Flask Clamp 41 7 1 3 Universal Platform Funnel Clamp 42 7 1 4 Universal Platform Microplate Holder 42 7 1 5 Universal Platform Test Tube Rack 42 7 1 6 Spring Wire Rack Flask ...
Страница 6: ...r circuit diagram 54 9 3 2 Shaker circuit diagram 55 9 3 3 External Refrigeration connection system ISF 7100 ISF 7200 56 9 3 4 Internal Refrigeration system ISF 7100R ISF 7200R 56 9 4 Disposing of products 57 9 5 Warranty 57 9 5 1 Terms of Warranty Service 57 9 5 2 Warranty exception 58 9 5 3 Service and technical advice 58 ...
Страница 7: ... service technician with specific experience with laboratory equipment and electricity 1 2 Symbols used in this Manual 1 The alert marks are for safety operation and protect user and instrument from Damage 2 Signal word panels are a method for calling attention to a safety messages or property damage messages and designate a degree or level of hazard seriousness 3 Pay attention enough to the conte...
Страница 8: ...talled the product on durable and flat surface Please make sure safety equipment with relevant provision before handling the sample which may cause flammable or toxic gases Do not use the machine near to places where explosion can be happened due to organic evaporating gases Explosive materials Acid Esther Nitro compound Inflammable materials salt peroxides inorganic peroxide salt acids Do not use...
Страница 9: ...oduct Also you cannot get after service by warranty regulation 1 5 Caution statement for safe use Indicates a hazardous situation which if not avoided may result in minor or moderate injury Be sure to disconnect the power after turning off the power switch This is the safety regulation for next user Do not put heavy things on the power line Do not put the machine on the line It may take off the wi...
Страница 10: ...lled from high frequency welding machine sewing machine and mass SCR controller Do not sprinkle insecticide or flammable spray on the product Use smooth cloths Cleaning with solvent can cause fire and deformity Please power off while product cleaning It may cause the electric shock or fire Wear protective gloves Wear eye protection No water No corrosive Electrical shock Flammable Foot crush Hand c...
Страница 11: ...trol PID feedback control ensures the same experimental environment conditions for the user The device s deviation of set temperature and set rpm are each under 0 1 standard 37 1 standard set rpm which are regarded as very precise value If the deviations go above a certain level alarm will be activated to the user 2 Control range of temperature and stirring speed is wide Temperature control up to ...
Страница 12: ...h is connected to the port on the product s side 8 This equipment is more convenient when mounting desorption of the sample When shaking performance operation always starts and stops at a specified location the platform is fixed to easily replace the sample Also when you open the door the height of the chamber is similar to the general sink a shorter experimenter can also easily exchange samples 2...
Страница 13: ... close the door If a user does not shut a door so that five minutes passes and an alarm sound continuously rings And it blocks off the power to be authorized with a power switch and Off gets a power switch done and all blocks off 2 phase of the power supplied with to an each part of appliances and configuration does the safe state that only a Ground part is connected 3 Shaking Table Shaking table ...
Страница 14: ...n 9 Gas Spring To offer convenience for user during sample change gas spring is fixed to open door 10 Door Packing To absorb the shock when users open close door and to seal door to the chamber inside 11 Power Switch To ON OFF Unit main power 12 Temperature Limiter Temperature limiter is independently configured from the main controller The inner temperature of the chamber exceeds more than the se...
Страница 15: ...ide 15 Adjustable Foot and Caster Using an adjustable and retractable foot caster it is easy to move and fix the device 16 Power Input and Fuse Power input is connected to power cable Fuse protects the device from instantaneous overcurrent In case of fuse replacement check the rated power Refer to 5 4 Fuse Replacement 17 Refrigerating System ISF 7100R 7200R only It circulates refrigerant in the ch...
Страница 16: ...ler The In out ports refer to the figure are located on the back and bottom side of the device These brass push to connect fittings accept Ø 8mm OD hard wall tubing and provide access ports for external refrigeration The barb on the right is to drain out the condensate comes from evaporator Therefore please do not block the barb with other materials Refer to 3 5 Connection to Drain and 3 6 Connect...
Страница 17: ...ct carefully for any damage that may have occurred during shipping 4 Report any damage to your local Jeio Tech office or the distributor 3 2 Component 1 After unpacking check the components 2 In the case of omission of components contact to Jeiotech Item Figure Quantity Description Main Body 1 Fuse 250V 10A 2 JEIOTECH SOFTWARE CD 1 Cable for Communication USB 1 ...
Страница 18: ...tion 3 3 1 Space requirements It is essential that the product to be situated in an area where there is sufficient space for the product Below figures show the minimum space requirements needed to properly operate and maintain the product H 1700 mm W 1128 mm D 935 mm ...
Страница 19: ...40 41 104 Relative humidity not to exceed 80 Altitude not to exceed 2000m 6 562 feet Connect the product to earth grounded terminals only Please install on the sturdy surface laboratory which is set safety facility and make sure horizontal align correctly Do not use the Product near environments where flammable gas may leak Moving casters must be changed height adjustable foots so that the unit is...
Страница 20: ...tall it near the Heat devices like a Heater 2 Have enough space for door opening refer to 3 3 1 3 Please install it on the sturdy surface laboratory and do not throw down or gives a big shock 4 Locate it 1 5m away from any light devices and 30 CM away from the wall 5 Install it on the sturdy leveled surface to prevent abnormal turbulence and noise ...
Страница 21: ...at least 5mm from the bottom 3 Put the level on the top of the unit and check the horizontality Adjusting the caster 4 For fixing the status turn the nuts to the upside of the unit 5 In the case of move the unit follow the procedure in reverse Do not palce the unit on the tilted ground or not flat place Once the foot is not fixed and the unit is operated the unit and the sample could be in trouble...
Страница 22: ...stems With this in mind Jeio Tech has developed the ISF 7100 7200 so that it can be connected to external refrigeration systems To connect the unit to an external refrigeration source use Ø 8mm OD hard walled tubing such as nylon or polyethylene Note The ISF 7100 7200 controller does not have the ability to communicate with the external refrigeration source Use the following procedure to connect d...
Страница 23: ...om fitting Grab the tubing tightly and push towards the incubated shaker as you firmly push the collet release button with two fingers Continue to push the collect release button and pull the tubing out of the fitting ...
Страница 24: ...e picture bellow by Identification label Voltage is the 10 of applied voltage Connect the power with checking the voltage Phase Capacity Use the ground power for the connection Do no use the double cap or a current tap socket causing a damage on the cable and fire due to an overcurrent 110 120VAC 220 230VAC ...
Страница 25: ...e parameter acknowledge the manual 4 Quick Start Stop Touch button is the base Start Stop external button is installed on the controller for the user s convenience Function setting is available on the system setting Default shaking start stop 5 LED Lamp On Off the LED lamp 6 Power ON indicator Power is supplied 7 Temperature Control ON indicator Under the temperature controlling 8 Shaking Control ...
Страница 26: ...ture Display the temperature of inside of chamber 5 Actual RPM Display the present shaking speed 6 Back From main display to home display It is available when the unit is stop the operating 7 Power Ack In the case of the power is off for the supply faulty reason and the supply is back the previous operating is back It is auto restart function At the time Power Ack button is appeared on the display...
Страница 27: ...the color will be changed as yellow The unit provide USB port and RS 232 port The display is on when the computer is connected Report Only Slave Mode Door is opened LED lamp is on Mute function The setting is available by the General Setting 10 Lock The lock function is to prevent the not proper setting change Once touch the button the display is changed same as To unlock it touch twice of the but...
Страница 28: ...ers Move out from the setting mode with ESC button In the case of no touch for 10 seconds the display changed to the main automatically Check the PV RPM on the setting display is available right upper side The operating is maintained as previous during the setting Once the door is opened during the shaking operating the heater and fan is stopped Close the door before door error generating the prev...
Страница 29: ...lay once the timer is set and is on the display once the timer is not set Remaining time is on the display once the timer is set and accumulated time is on the display once the timer is not set 1 Timer ON Touch the Set timer on the main display Timer OFF is on the display once the timer is set and Timer on is on the display once the timer is not set Touch the Timer ON button and set the time on th...
Страница 30: ... the main automatically On the timer set display you can check the present chamber temperature and rpm right upper side of the display Below 1 minutes is displayed as mmm ss Timer is not counted during the door open 4 2 4 Alarm and Stop by force The unit senses the problem on the unit and warn to the user The warning is visual audial effect The alarm is divided into warning and fault 4 2 4 1 Warni...
Страница 31: ...arm is generated 3 Load Unbalance Once the shaking system is vibrated by the present operating the system adjusts the shaking speed to the controllable stage This is on the display 4 Door Open Once the door is opened the temperature and rpm are not operated Once the door is opened visual audial alarm is generated After 3 minutes of door opening the alarm is effective Once the door is closed alarm ...
Страница 32: ...rature Limit Electronic Mechanical over temp Limiters on the right side of the unit is activated The inner temperature of the chamber exceeded the set temperature of the limiter The unit stops operation for protection of the product and the samples Check the range of the set temperature of the over temp limiters 2 Load Unbalance This error occurs when shaking operation cab not be activated due to ...
Страница 33: ...t the general operating Touch General Setting button and below setting menu is appeared Touch the or and explore the menu 1 Shaking Direction Set the shaking direction CW clock wise CCW counter clock wise 2 Temperature Unit C F 3 Lock Use the Lock or not 4 System Sound Mute for sound or not 5 LCD Brightness Adjust the brightness of LCD 6 LCD Auto Dim LCD Dim function No input LCD dim 7 Dim Brightn...
Страница 34: ...erature and rpm The time of out of deviation limit range can be set either 1 Temperature Deviation Limit Set the deviation limit between setting value and actual value Set on the key pad 2 Temperature Deviation Alarm Delay Once the deviation is out of range for alarm delay period the alarm is generated Once the actual temp reached to the set temp the alarm is disappeared after alarm delay period c...
Страница 35: ...perature sensor of main controller The unit provides three points calibration Each point of three shows the uncalibrated and calibrated status Touch the point you want to change Touch the one point of Calibration 1 2 3 Put the external sensor on the chamber and close the door Touch the temperature on Set Temp and put the desired temperature on it and operate the unit Wait until the actual temp rea...
Страница 36: ...ated means the temp that calibrated The calibrated value is from the external sensor The calibration setting is available to be initialized on the System Setting Reset 4 4 3 2 Shaking Speed Calibration ISF models with Direct Drive Shaking does not need RPM Calibration 4 4 3 3 Touch Screen Calibration Touch penal coordinate could be in the problem for the reason of the older unit and the problem in...
Страница 37: ...ition Sensor Check the platform stop on the right position 2 Stall Check Check the belt when the platform is not working properly 3 Defrost Use Defrost is not for the IST model Off the defrost use 4 Load Unbalance Once the vibration is generated the shaking speed is adjustable 5 Threshold Load Unbalance check the vibration on the unit and adjust the rpm automatically The vibration is on the range ...
Страница 38: ...amber over set temp the operation discontinues 4 5 2 High Low Temp Limiter This model has electric High Low Temp Limiter additionally Over Temp limiter is operated mechanically But Electric High Low Temp Limiter make operation stop by receiving high low value from user If PV is out of high low value it is supposed to be stopped Please refer to Appendix 9 2 regarding how to use electric High Low Te...
Страница 39: ...system connection ISF 7100 ISF 7200 Incubator Set temperature and actual temperature difference Auto Tuning Temperature setting Temperature correction Actual temp Display temp correction Air filter clean ISF 7100R ISF 7200R PC Sync operation Controller and timer operation System Connection between platform and accessories Connection between platform and shaking table Actual rpm Display rpm correct...
Страница 40: ...ding Especially socket and controller part it can make short circuit problem 4 After discussion the proper cleaning method to avoid any damage for the machine with Jeiotech if you want to clean the machine or remove the polluted area with not mentioned cleaning method before the clean 5 The inside electric part of the machine should be handled by Jeiotech or person who is delegated by Jeiotech 6 I...
Страница 41: ...isassemble air filter which is combined with condenser cover Step 5 Vacuum or clean the air filter with the water Step 6 Vacuum or high pressure air clean to the condenser in the machine It makes better refrigeration effect Step 7 Assemble air filter in reverse order of Step 1 Step4 When air filter clean please be careful to avoid fold the condenser pin It is possible to decrease refrigeration eff...
Страница 42: ...n A Fuse A Fust Cat No ISF 7100 230VAC 50 60Hz 5 10 00CDE0005543 120VAC 60Hz 9 5 15 00CDE0005541 ISF 7200 230VAC 50 60Hz 5 10 00CDE0005543 120VAC 60Hz 9 5 15 00CDE0005541 ISF 7100R 230VAC 60Hz 7 2 10 00CDE0005543 230VAC 50Hz 7 2 10 00CDE0005543 120VAC 60Hz 13 9 15 00CDE0005541 ISF 7200R 230VAC 60Hz 7 2 10 00CDE0005543 230VAC 50Hz 7 2 10 00CDE0005543 120VAC 60Hz 13 9 15 00CDE0005541 Fuse is located...
Страница 43: ...th can be occurred Step 1 Press power switch and Power off Step 2 Connect screw driver to fuse holder Spin the fuse holder counterclock wise 50 then fuse holder is disassembled Step 3 Compare the fuse specification with the above table and replace it if there is no problem Step 4 Complete the replacement in reverse order of Step 2 퓨즈 교체 반시계방향으로 50도 회전 드라이버 삽입 ...
Страница 44: ...erating and the normal shaking is not available To prevent the shaking system stop the shaking Check the unbalanced sample setting overload un flat ground Door Open Door is opened over 5 minutes during the operating Close the door and touch the start button and restart the unit Sensor Fault Temperature sensor is faulty so the operating is stopped Contact the manufacturer or sales point Over Curren...
Страница 45: ...f incubator rise to setting value Check the Temperature Control ON indicator is ON Check outdoor temperature is too high or low and maintain the right room temperature Request A S after check the difference between actual temperature and display temperature Check the door switch irregularity Request A S if the heater is out of order Request A S if the freezer is out of order Check air filter condi...
Страница 46: ...erated after shaking start button press Check Timer close status if shaking is not operated after shaking start button press cancel timer set up If the problem is not fixed with the above method please request A S Noise Check fixed condition of platform or sample Check the weight of sample is shifted to one side relocate the samples evenly If the problem is not fixed with the above method please r...
Страница 47: ...mp Model Flask Clamp ISF7000 series 50ml 88 100ml 54 250 300ml 35 500ml 24 1 000ml 15 2 000ml 11 2 800ml 6 4 000ml 6 6 000ml 5 7 1 2 Universal Platform Plastic Flask Clamp Model Flask Clamp ISF 7000 series 50ml 88 100 125ml 48 200ml 35 250ml 35 300ml 35 500ml 23 1 000ml 12 2 000ml 6 ...
Страница 48: ... ISF7000 series 250ml 15 500ml 10 1 000ml 7 2 000ml 5 7 1 4 Universal Platform Microplate Holder Model Type ISF7000 series Single 24 Tower 21 Flat A large 4 Flat B small 6 7 1 5 Universal Platform Test Tube Rack Model Type ISF7000 series 0 7 15 7 30 7 45 6 60 6 ...
Страница 49: ...form Flask ISF7000 series 50ml 40 100 125ml 28 250 300ml 15 500ml 10 1 000ml 8 2 000ml 4 2 800ml 4 About the right position for mounting maximum quantity of Accessories please visit Jeio Tech website or contact our office and distributor ...
Страница 50: ...1 Monitoring Program installation 1 Put the installation CD on the CD ROM drive then the program is operated automatically Click the Next button go to the License Agreement 2 Check the details and click the I agree ...
Страница 51: ...nstall and install the program 4 Once the program is installed below window is up and JeioTechSoft icon is generated on the background Check the Run JeioTechSoft 2 0 0 5 or double click the icon then the program starts ...
Страница 52: ...efer to below reference Communication Reference http www modbus org docs Modbus_Application_Protocol_V1_1b3 pdf 8 2 1 Physical Layer Communication port RS 232C USB 8 2 2 Model System number ITEM System Number System Model Number Incubated Shaker 1601H Shaking incubator ISF 7100 1602H Shaking incubator ISF 7100R 1603H Shaking incubator ISF 7200 1604H Shaking incubator ISF 7200R ...
Страница 53: ...eviation 4 8 W S R I 33 MOD_TEMP_D EVI_ALARM 0 3599 temp devi alarm time 1 2 W S R I 34 MOD_RPM_D EVI rpm devi min rpm devi max rpm deviation 1 2 W S R I 35 MOD_RPM_D EVI_ALARM 0 3599 rpm devi alarm time 1 2 W S R I 36 MOD_EXT_KE Y 0 2 external key operation 1 2 W M R I 37 MOD_SET_TE MP low temp lmt high temp lmt incubator set temp 4 8 W S R I 41 MOD_SET_RP M rpm min rpm max shaker set rpm 1 2 W M...
Страница 54: ...emp lmt temp_d evi_ma x temp_d evi_min R I address 16 17 18 19 max rpm min rpm rpm_de vi_max rpm_de vi_min MOD_SYS_SOUND Set the system sound modbus function code 0 return data 0 R I address upper lower sound flag modbus function code 0 r w data 0 sound off W S data 1 sound on MOD_SYS_LAMP Set the lamp brightness modbus function code 0 return data 0 R I address upper lower lamp bright modbus funct...
Страница 55: ...ode 0 return data 0 R I addres s temp devi alarm modbus function code 0 value 0 3599 sec W S value MOD_RPM_DEVI rpm deviation modbus function code 0 return data 0 R I addres s rpm devi modbus function code 0 value rpm devi min max W S value MOD_RPM_DEVI_ALA RM rpm devi alarm time modbus function code 0 return data 0 R I addres s rpm devi alarm modbus function code 0 value 0 3599 sec W S value MOD_...
Страница 56: ...set time modbus function code 0 1 value 0 3599940L 1min W M value MOD_SHAKER_TIME_O NOFF shaker timer on off set modbus function code 0 data 0 shaker timer off W S data 1 shaker timer on MOD_INCUBATOR_RUN _STOP incubator operation set modbus function code 0 data 0 incubator stop W S data 1 incubator start MOD_SHAKER_RUN_ST OP incubator operation set modbus function code 0 data 0 shaker stop W S da...
Страница 57: ... mute refrig sens or opt warn door warn otp door open error 7 6 5 4 3 2 1 LSB usb connec t silent disp sk pos er lamp timer shaker incubat or operation on of f on off op_fla g op_flag sys op MOD_WARN_ACK warn message clear modbus function code 0 data 1 message clear W S data 0 operation none MOD_SILENT_ACK Mute modbus function code 0 data 1 beep stop W S data 0 operation none MOD_AUTO_ACK auto run...
Страница 58: ...rushless Motor and Triple Cam system Material Internal Stainless Steel 0 8t External Steel 1 0t 1 2t powder coating Platform Anodized aluminum plate 5 0t Insulation Expanded Poly Styrene 45t Lid Viewing window Heater Incoloy Fin Type 550W X 2EA 1 100W Safety Device CLS Custom Logical Safe control system Electronic temperature limiter Hydraulic over temperature limiter Temperature deviation alarm H...
Страница 59: ...ters back to basic display by Up Down and SET button simultaneously It is available to set the range of limit H L temp in Parameter setting display press SET button over 2sec in Basic display LOW T HIGH T Unit Checking parameter value by SET button and set the value by Up Down High Limit 10 High Limit C Low Limit Low Limit 120 도 C Stand by over 5 sec or back to basic display by SET button Revise t...
Страница 60: ...54 9 3 Circuit Diagrams 9 3 1 Incubator circuit diagram ...
Страница 61: ...55 9 3 2 Shaker circuit diagram ...
Страница 62: ...56 9 3 3 External Refrigeration connection system ISF 7100 ISF 7200 9 3 4 Internal Refrigeration system ISF 7100R ISF 7200R ...
Страница 63: ...ment 2 Please contact your local governing body for regulations regarding disposal of electrical electronic metal brass aluminum steel and stainless steel refrigeration and rubber components Jeio Tech recommends the user find a local scavenger or laboratory equipment recycler to properly dispose of the unit and its components 9 5 Warranty 9 5 1 Terms of Warranty Service 1 Customer can get free war...
Страница 64: ...ruse of voltage or earthshock If the product is broken without taking care of the Notice alerted on the manual 9 5 3 Service and technical advice We Jeiotech Co Ltd are doing best to give best support based on customer service system When we get the symptoms fault states contact number by customer we offer after sales service International Sales Head Office Korea 1005 Byucksan Digital Valley 6 Cha...
Страница 65: ...anghai Branch B 705 Jingting Bldg No 1000 Hongquan Rd Minhang district Shanghai P R CHINA 201103 Tel 86 21 5108 9161 5414 8389 Fax 86 21 5168 5414 E mail longjuncao jeiotech com South East Asia Malaysia Branch No 57 59 Jalan Adenium 2G 6 Pusat Perniagaan Adenium 48300 Bandar Bukit Beruntung Selangor Darul Ehsan Malaysia Tel 60 3 6021 6880 E mail lcomp99 po jaring my FAX 60 3 6021 7880 Product is s...