background image

•  FIRST AID – SKIN: If battery acid comes in contact with skin, rinses immediately with water, then wash thoroughly with soap and water., If redness, 

  pain, or irritation occurs, seek immediate medical attention.

  FIRST AID – EYES: If battery acid comes in contact with eyes, flush eyes immediately, for a minimum of 15 minutes and seek immediate medical attention.

  IMPORTANT: Have someone nearby in case of accidents or mishaps.

•  Prior to use, read and understand all warnings, cautions and instructions included in all instruction manuals and those published by your vehicle 

  battery manufacturer.

•  Failure to follow all instructions listed in this instruction manual may result in property damage, fire, electric shock and/or injury to yourself or others.

•  Dry location with overhead cover use only! Do not use maintainer in damp or wet locations. Do not use manitainer in the rain.

•  Keep children and non-suspecting persons or pets away from the battery working area.

•  Do not force the maintainer. This unit is designed for optimum performance and safety at 3 Amps Charge Rate.

•  Never carry the maintainer by the power cord. Keep power cord away from heat, oil, and sharp edges.

•  For added safety performance it is recommended that the maintainer be connected to an AC outlet that is protected by a Ground Fault Circuit 

  Interrupter (GFCI).

•  Do not operate the maintainer near flammable materials or any location, which accumulate flammable fumes.

•  This product contains chemicals, including lead, known to the State of California to cause cancer and birth defects or other reproductive 

  harm. Wash hands after handling!

•  Battery posts, terminals and related accessories contain lead and lead compounds, chemicals known to the State of California to cause cancer and 

  reproductive harm. Batteries also contain other chemicals known to the State of California to cause cancer. Wash hands after handling!

•  All lead acid batteries (car, truck, boat, etc..) produce hydrogen gas, which may violently explode in the presence of fire or sparks, Do not smoke, 

  use matches, lighters or open flame near  batteries.

•  Working around lead acid batteries may be dangerous. Lead-acid batteries generate explosive gases during normal charging operations.

•  Use this product with 6 or 12 Volt lead-acid batteries only. Do not connect to 24 Volt batteries.

•  BURST HAZARD! Do not use this unit to charge dry-cell batteries. These type of batteries may burst and cause injury to persons and property damage.

•  Do not submerge this unit in water or expose unit to snow or heavy moisture.

•  To reduce risk of electric shock, disconnect the unit from any power source before attempting maintenance or cleaning. Powering OFF controls 

  without disconnecting will not reduce this risk. 

•  Do not charge a 6 or 12 Volt lead-acid battery while the vehicle engine is operating.

•  Do not operate the maintainer on boats, boat ramps or docks since the electrical power cords and outlets used for connecting could cause 

  severe electrical shock if they get wet.

•  Stay clear of fan blades, belts, pulleys and moving parts that can cause bodily injury during battery charge operations.

•  Keep clips battery post connections cables and power cable away from fan blades, belts, pulleys and moving parts during in-vehicle battery 

  charge operations.

•  Wear complete eye and clothing protection. Do not touch eyes while working around lead-acid batteries.

•  When connecting or disconnecting the maintainer, pull on the plug not on the power cord.

•  Avoid dropping metal tools or objects on top of 6 or 12 Volt batteries. It might spark or short-circuit the battery or other electrical part that may 

  cause short-circuits or explosion.

•  Remove personal metal items, such as rings, bracelets, necklaces and watches while working with lead-acid batteries. It can produce a short-circuit 

  high enough to cause a severe burn.

•  Never charge a frozen battery. 

•  Never allow battery acid to come in contact with this unit.

•  When working with lead acid batteries, always make sure immediate assistances is available in case of accident or emergency.

•  Risk of Electric Shock! Do not open unit casing. This product has no user serviceable parts. In the event of operational malfunction or damage, the 

  unit must be returned to the manufacturer for professional testing and repair. Opening the unit casing will void the manufacturer’s warranty.

•  Operate this product in a clear, dry, open and well ventilated area.

•  Adult operation only. Not to be operated by children!

•  Place unit a minimum of 18 inches above ground level when operating in a garage or similar environments. 

•  Do not operate this unit with a damage power cord.

•  Use only the provided parts or attachments supplied, recommended or sold by the manufacturer specifically for use with this unit. Unauthorized 

  parts may damaged the unit or result in electric shock and bodily injury.

•  Save these instructions for future reference.

No. 81954

3A BATTERY MAINTAINER

IMPORTANT SAFETY INSTRUCTIONS

WARNINGS

CAUTIONS

KEYED

CONNECTOR

7.5 AMP

IN-LINE

FUSE

BATTERY CLIPS

6FT. CABLES

6FT. POWER 

CORD

DIGITAL DISPLAY

6 VOLT SELECT

FAULT LED

POWER BUTTON

(MANUAL 6V/12V SELECTOR)

12 VOLT SELECT

Содержание 81954

Страница 1: ...ubmerge this unit in water or expose unit to snow or heavy moisture To reduce risk of electric shock disconnect the unit from any power source before attempting maintenance or cleaning Powering OFF controls without disconnecting will not reduce this risk Do not charge a 6 or 12 Volt lead acid battery while the vehicle engine is operating Do not operate the maintainer on boats boat ramps or docks s...

Страница 2: ...D INDICATOR A green LED indicates that a 6V battery is being charged A green LED indicates that a12V battery is being charged A red LED indicates that a fault occurs BATTERY MAINTAINER FUNCTIONS JEGS 3A Battery Maintainer No 81954 has a charge rate of up to 3 amps It is designed for charging small batteries and maintaining large batteries It is designed for 6 and12 Volt lead acid batteries only co...

Страница 3: ...arging capacity refer to the Approximate Charging Times section for battery charging durations 2 As the battery nears full charge capacity the unit s output charge rate will automatically drop and FUL will show 3 The battery is fully charged and enters the Stage Three Automatic Float Charging AUTOMATIC FLOAT CHARGING NOTE Automatic Float Charging is ideal for maintaining a fully charged battery 1 ...

Страница 4: ...e Charging in cold temperatures will increase the amount of time required to charge a battery Find your battery s CCA rating in the table below and note the charging time The time reflects a battery with at least 50 charge You may need to add time depending on the severity of discharge CARE AND MAINTENANCE Withproper careandminimalmaintenance theJEGS 3A Battery Maintainer No 81954will provide year...

Страница 5: ...a unidad en agua ni exponga la unidad a la nieve o humedad extrema Para reducir el riesgo de descarga eléctrica desconecte la unidad de cualquier fuente de potencia antes de intentar el mantenimiento o limpieza Los controles del interruptor de apagado sin desconectar la unidad no reducirán este riesgo No cargue una batería de plomo ácido de 6 ó 12 voltios mientras el motor del vehículo esté funcio...

Страница 6: ...tería de 6 voltios se está cargando Una luz LED verde indica que una batería de 12 voltios se está cargando Una luz LED roja indica que una occure una falla FUNCIONES DEL CONSERVADOR DE BATERÍA El conservador de 3A de JEGS No 81954 tiene un nivel de carga de hasta 3 amperes Está diseñado para cargar sólo baterías pequeñas y conservar baterías grandes Está diseñado para baterías de ácido de plomo d...

Страница 7: ...ivelada 2 Coloque el conservador de baterías tan lejos de la batería como lo permitan los cables IMPORTANTE a NUNCA coloque el conservador de baterías directamente arriba de la batería que va a cargar los gases de la batería corroerán y dañarán el conservador de baterías b NUNCApermitaqueelácidodelabateríagoteesobreelconservador alleerlagravedadespecíficaoalllenarlascélulasdelabatería c NUNCA haga...

Страница 8: ...una carga Cargar en temperaturas frías incrementará el tiempo requerido para cargar una batería Encuentre la tasa de amperes en arranque en frío AAF de su batería en la tabla siguiente y apunte el tiempo de carga Los tiempos reflejan una batería con por lo menos 50 de carga Puede ser necesario agregar tiempo dependiendo de la severidad de la descarga CUIDADO Y MANTENIMIENTO Con un cuidado apropiad...

Отзывы: