background image

 
 

 

   

ECO Pump 

OWNER’S MANUAL 

TSP-10000

TSP-15000

TSP-20000, TSP-30000 

Introduction

 

The  pumps  are  carefully  inspected  and  tested  to  ensure  both  safety  and  operating 
performance. However, failure to follow the instructions and warnings in this manual 
may  result  in  pump’s  damage  and/or  serious  injury.  Be  sure  to  read  and  save  this 
manual for future reference. 

Control and Panel Function   

 
 

1, LED display and controller key Instructions 

As indicated in able diagram LED indicates power work/stop and fault code, the panel 
are touched control A, B, C indicates work/stop, slow, faster. 
 

2, Operating instructions 

Connected with pump, Plug on the power. LED show “ P****”, P is short for power, 
up to up until to the Max. watts of the pump. Such us, P0010 means 10 watts. Touch 
the button “

/

” LED shows “ F***” F is short for Speed. There is from 

F0030-F0100, F0031, F0032, F0033…, total 70 speed to adjust the flow rate.   
 

3, The key Lock Function 

Press “

”button, the pump stop for feed. Press “

” button again, pump resumes 

working, LED shows normal locking panel. Press “

” button for three seconds until 

the LED flash twice. The controller locked. Lock the pump in the setting data working 
condition. Press the “

”button for three seconds again. LED flash twice. The 

controller unlocked. 
 

4, The LED protected mode 

The controller enters the screen saver mode after 25 seconds if no any touch of the 
screen, the LED screens becomes to micro bright. The LED return to normal brightness 
when press any button. 

 

5, Date memory function 

If no power to cause the pump stops suddenly, when power on, the pump resumes 
working as previous setting parameter. 

6, Fault code and description 

The abnormal working code and flashing of the controller.   
the code explanation as below: 

Er01:

 Current abnormally; 

Er02:

 Controller overheating; 

Er03:

 Pump working without water

 

Er04:

 Something blocks the pump, the impeller stop running; 

Er05:

 The voltage is abnormal, too high or too low. 

 
7, Controller installation 

Something blocks the pump Install the controller on the floor in horizontal, or on the 

wall in vertical. Fix it with screws then put the plug into the socket, lock the nut. 

 

Note:  for  outdoor  use,  the  power  socket  must  be  installed  with  the  leakage  current 

protecting device, and the leakage current shall not exceed 30mA (please the consumer 
to install the leaking current protection device by themselves). 

 
Performance Parameters Table

 

No.: 

Model    No: 

Voltage 

Control box             

(W) 

 

Consumption 

(W) 

 

Flow    rate 

(L/H) 

 

Head Max 

(M) 

TSP-10000 

AC220-240V 50/60Hz 

100 

85 

10000 

5.0 

TSP-15000 

AC220-240V 50/60Hz 

200 

135 

15000 

6.0 

TSP-20000 

AC220-240V 50/60Hz 

200 

185 

20000 

7.0 

TSP-30000 

AC220-240V 50/60Hz 

385 

385 

30000 

10.0 

 
CAUTION 

Always disconnect the pump from the power supply before cleaning, maintenance and 
handling. 
Do not let the pump work dry. 
Do not lift the pump by holding the power cord only 
Do not use the pump in the heating liquid. 
The pump fits for fresh water and sea water only 
Please use the pump only when it is completely submerged in water. 
The pump can not run in the swimming pool. 
Automatic shut off if no water for 2 minutes. 
Pull the plug out, and re-insert for resuming work. 