Introduction
The pumps are carefully inspected and tested to ensure both safety and operating
performance. However, failure to follow the instructions and warnings in this manual
may result in pump’s damage and/or serious injury. Be sure to read and save this
manual for future reference.
Control and Panel Function
1, LED display and controller key Instructions
As indicated in able diagram LED indicates power work/stop and fault code, the panel
are touched control A, B, C indicates work/stop, slow, faster.
2, Operating instructions
Connected with pump, Plug on the power. LED show “ P****”, P is short for power,
up to up until to the Max. watts of the pump. Such us, P0010 means 10 watts. Touch
the button “
▲
/
▼
” LED shows “ F***” F is short for Speed. There is from
F0030-F0100, F0031, F0032, F0033…, total 70 speed to adjust the flow rate.
3, The key Lock Function
Press “
Ⅱ
”button, the pump stop for feed. Press “
Ⅱ
” button again, pump resumes
working, LED shows normal locking panel. Press “
Ⅱ
” button for three seconds until
the LED flash twice. The controller locked. Lock the pump in the setting data working
condition. Press the “
Ⅱ
”button for three seconds again. LED flash twice. The
controller unlocked.
4, The LED protected mode
The controller enters the screen saver mode after 25 seconds if no any touch of the
screen, the LED screens becomes to micro bright. The LED return to normal brightness
when press any button.
5, Date memory function
If no power to cause the pump stops suddenly, when power on, the pump resumes
working as previous setting parameter.
6, Fault code and description
The abnormal working code and flashing of the controller.
the code explanation as below:
Er01:
Current abnormally;
Er02:
Controller overheating;
Er03:
Pump working without water
;
Er04:
Something blocks the pump, the impeller stop running;
Er05:
The voltage is abnormal, too high or too low.
7, Controller installation
Something blocks the pump Install the controller on the floor in horizontal, or on the
wall in vertical. Fix it with screws then put the plug into the socket, lock the nut.
●
Note: for outdoor use, the power socket must be installed with the leakage current
protecting device, and the leakage current shall not exceed 30mA (please the consumer
to install the leaking current protection device by themselves).
Performance Parameters Table
No.:
Model No:
Voltage
Control box
(W)
Consumption
(W)
Flow rate
(L/H)
Head Max
(M)
1
TSP-10000
AC220-240V 50/60Hz
100
85
10000
5.0
2
TSP-15000
AC220-240V 50/60Hz
200
135
15000
6.0
3
TSP-20000
AC220-240V 50/60Hz
200
185
20000
7.0
4
TSP-30000
AC220-240V 50/60Hz
385
385
30000
10.0
CAUTION
Always disconnect the pump from the power supply before cleaning, maintenance and
handling.
Do not let the pump work dry.
Do not lift the pump by holding the power cord only
Do not use the pump in the heating liquid.
The pump fits for fresh water and sea water only
Please use the pump only when it is completely submerged in water.
The pump can not run in the swimming pool.
Automatic shut off if no water for 2 minutes.
Pull the plug out, and re-insert for resuming work.