background image

                                                                         

Smart DC Pump

 

 

 

MDP      Series

 

WARNING

 

●Please use the matched adapter and related accessories.

 

●Do  not  put  the  pump  in  the  flammable,  explosive  and 

corrosive liquid. 

●Do not use the pump in the water temperature above 35

●Maximum water depth 1.5M.

 

●Do not immerse the plug into water or other liquid. 

●Do not allow children or the inexperienced to operate and 

play the product alone without safety guarantee.

 

●Please refer to actual products and APP.

 

 

 

 

 

Содержание MDP Series

Страница 1: ...Smart DC Pump USER MANUAL MDP Series MDP 2500 MDP 3500 MDP 5000 MDP 6000 MDP 8000 MDP 10000 MDP 13000 MDP 15000 MDP 20000 ...

Страница 2: ... flammable explosive and corrosive liquid Do not use the pump in the water temperature above 35 Maximum water depth 1 5M Do not immerse the plug into water or other liquid Do not allow children or the inexperienced to operate and play the product alone without safety guarantee Please refer to actual products and APP ...

Страница 3: ...ump Features Wi Fi Manual dual function controller Smart life No electronic device inside of the pump longer life Sine Wave Technology ultra quiet operation Power display and flow control Automatic power off protection upon no water Suitable for both marine and fresh water Rust free II Products use Used as submersible pump the water level should exceed the inlet of the pump to avoid pumping the ai...

Страница 4: ... cover to connect the water pipe in inlet and outlet to ensure water in the pump and pipe before plug on OPERATING INSTRUCTION When use the pump please pay attention to the position of the pump Please connect the pump supply after finishing the installation If the pump can t pump the water out for the first time which may be caused by the air in the pump body Please try to plug off and re plug on ...

Страница 5: ... The pump fits for both fresh water and marine water The pump can be used as submersible pump and non submersible as long as ensure the pump filled with water The pump can t be used in the swimming pool This product has multiple protection function When it enters the protection state please plug off and plug on to recover the pump normal work III Controller Features Adjustable the flow rate and he...

Страница 6: ... Function Description After power on the pump the display screen will come the WIFI icon operating power and working step The operating power shows P W The flow rate shows 71 steps F30 100 Push the button to adjust the flow rate Wi Fi button Display Screen Flow turn down Feed Pause Flow turn up ON OFF ...

Страница 7: ...mp stops working then press button again the pump starts to work Remarks When the pump enters to the timer mode in APP if keep pressing button for seconds to exit the timer mode 2 The Button Lock Function Under the pump power on long press the button for 3 seconds the lock icon willshow on the display and all the button will be locked Long press the button again for 3 seconds and the lock icon in ...

Страница 8: ...rightness the button to adjust the screen saver brightness 4 Data memory function When power off the controller the controller keeping the same default parameter in memory after reworking 5 Wi Fi icon description and usage A Wi Fi icon flashes while the Pump is on smart configuration mode B Wi Fi icon and AP icon flashing synchronous when the Pump is on AP configuration mode C Wi Fi icon is keepin...

Страница 9: ...i with AP icon flashes in the upper left of the screen C Then long press the Wi Fi button for 5 seconds again the Wi Fi switches to the smart configuration mode D The WIFI icon shows on the upper left always when connect the WIFI successfully IV APP Download and Instruction 1 Download The APP name Jebao Aqua is available to download in App Store for Apple users or Google Play for Android system us...

Страница 10: ...an the barcode on the package or user manual to download the application Note Scan function in certain countries or areas may be unavailable to read the barcode properly 2 User registration login and password reset 2 1 Account registration ...

Страница 11: ...tion return back to the login page enter the account and password to log in Note Phone number registration is valid for mainland China only 2 2 Reset Password Tap Forget Password on the log in page Enter your email address and tap Send link Check your email and follow the instructions to reset your password Then back to the log in page to input your account and new password to log in ...

Страница 12: ...Smart DC Pump MDP Series 11 V App Application 1 Main page Go to My Group Go to Setting Add new devices Add new devices ...

Страница 13: ...Smart DC Pump MDP Series 12 2 Add new pump Tap Add Now or tap the top right icon to add your device tap the Aqua Pump Icon Tap My Devices ...

Страница 14: ...ration and AP configuration modes Choose one mode to link your device Smart Configuration mode After the device power on the Wi Fi icon on the upper left flashing the device enters the smart configuration mode When see the screen upper left side WIFI icon flashing Choose the confirmation Device is in smart configuration mode then tap Next start to smart configuration ...

Страница 15: ...ons Enter Wi Fi password and tap Next Make sure your device phone and the router are as close as possible during the configuration process The page will display all the devices Choose the request add device tap the device name then tap Confirm to add ...

Страница 16: ...press the Wi Fi button for 5 seconds before distributing network see the Wi Fi with AP icon flashes on the upper left of the screen then the device enters the AP network distribution mode Tap AP Network in the upper right corner on APP adding device page as above to enter into AP configuration ...

Страница 17: ...Smart DC Pump MDP Series 16 Choos the confirmation Device is in AP configuration mode and tap Next Enter the correct Wi Fi password and tap Next ...

Страница 18: ...rent operating system IOS and Android will operate differently in the following details A IOS System After entering the Wi Fi password you need to switch manually the phone Wi Fi to Jebao_WiFi xxxx the specific operation as below Tap Go to settings ...

Страница 19: ...ap Settings in the upper left corner to enter the mobile phone settings page then enter the WIFI setting page as below Go to WIFI Settings page choose the Jebao_WiFi xxxx with password 123456789 Connecting the Jebao WiFi 123456789 ...

Страница 20: ...C Pump MDP Series 19 After connection successfully return back to the APP Enter into the APP The configuration starts automatically Tap Start to control the device after the device has been added successfully ...

Страница 21: ...The device will be displayed Tap Start to control the device after the device has been added successfully Remarks A Before distributing network open the phone location and the corres ponding permissions B You may be asked to restart configuration process again if put the wrong Wi Fi password C Try to put the device mobile phone and router are placed as close as possible D The WIFI icon shows on th...

Страница 22: ...con for 2 seconds to enter the pump control page Manual mode Drag the arc progress bar stop draging then effective Change the gear value of the pump The minimum step is 30 and the maximum step is 100 Long press the icon for 2 seconds ON OFF button Manual control bar Current gear value Feed icon Program icon ...

Страница 23: ...Manual feeding mode The pump will stop working immediately when arrive the feeding time Press the Feed icon for 2 seconds to enter the feeding settings Set the feeding pause time turn on the feeding switch then tap save and return ...

Страница 24: ... seconds to enter the setting page and set the working mode of the pump at various time every day including the pump stop automatic and feeding mode Tap the Stop or Auto Feed icon or tap the circle twice to edit the each time period Tap the circle twice Choose the mode ...

Страница 25: ...atically add the plan time period Choose the work mode of the plan time period Drag the slider to adjust the start and end time or to modify start and end time directly Tap Done to save the plan setting If want to delete the current setting period then tap delete Time switch button End time setting Start time setting Mode selection Gears setting Adjust time slider ...

Страница 26: ... and tap the plan icon to run the program mode PS The plan mode will be closed if you set the flow stage by manual Plan mode effective after ending the slide 4 Rename and delete the pump Tap the upper right corner of the device as above picture The device can be renamed and deleted ...

Страница 27: ...Pump MDP Series 26 The user can change the pump name as want for easy management The user can delete the current pump also But when want to add the pump again need to reconfigure the network 5 Failure indicaton ...

Страница 28: ...g current Check if the pump cable short of voltage or the controller broken Er02 Controller overheating Check whether the controller exposed to the sunshine or under high temperature environment Er03 The pump dry running Check if the pump run dry without water Er04 The pump was blocked Check if the impeller is blocked clean the pump and impeller to ensure the impeller clean and work Er05 Controlle...

Страница 29: ... Clean the rotor remove the dirt etc The power cord of the pump must be under the power socket to form a drip ring to prevent water into the power socket along the power cord DISPOSAL Please don t dispose this product as unsorted municipal waste Collection of such waste separately for special treatment is necessary Not put it together with the domestic waste which should be solved as an authorized...

Страница 30: ...Jebao Co Ltd Add Tongmao Industrial Park Dongsheng Town Zhongshan Guangdong China Tel 86 760 28136708 28136720 E mail info jebao com Website http www jebao com ...